PROGRAMMING
3
Factory default settings for the
NORMAL FLUSH
are as follows:
Sequential mode: T1= 3 sec, T2= 3 sec, T3= 2 sec
Continuous mode: T1= 3 sec, T2= 12 sec, T3= 2 sec
Step 1 - Entering program mode:
Hold the WATER ONLY
and
EMPTY ONLY
buttons down together for 3 sec-
onds. The Holding Tank Full LED will flash THREE
times indicating you have entered program mode -
release both button.
Setting T1 initial fill time:
After entering program mode (Step 1 above) push
the NORMAL FLUSH
button once. Continue to
press the NORMAL FLUSH
button equivalent
to the number seconds you wish water to enter the
bowl: (one push= 1 second, 2 pushes= 2 seconds,
etc.). The Tank LED will flash after each valid key
push. The maximum inlet time is 20 seconds. When
finished, push the EMPTY ONLY
button to store
this value and exit. The Holding Tank Full LED will
flash THREE times indicating you have left program
mode.
Setting T2 Discharge Pump Time:
After entering program mode (Step 1 above) push
the EMPTY ONLY
button once. Continue to
press EMPTY ONLY
button equivalent to the
number of seconds you wish water to exit the bowl:
(one push= 1 second, 2 pushes= 2 seconds, etc.). The
Tank LED will flash after each valid key push. The
maximum empty time is 20 seconds. When finished,
push the NORMAL FLUSH
button to store this
value and exit. The Holding Tank Full LED will
flash THREE times indicating you have left program
mode.
Setting T3 Water Retention Fill Time:
After placing the unit in program mode (step 1) push
the WATER ONLY
button once. Continue to
press the WATER ONLY
button as follows to
leave water standing in the bowl: (1 push= ZERO
seconds, 2 pushes= 2 seconds, 3 pushes= 3 seconds,
etc).
Disabling the WATER ONLY
and
EMPTY ONLY
buttons (Wall switch
model only):
When in the factory default mode, both the
WATER ONLY
and EMPTY ONLY
buttons will only operate for maximum of eight
seconds. The procedure below will disable these
buttons completely if desired:
1. Hold the WATER ONLY
and EMPTY
ONLY
buttons down together for 3 seconds.
The Holding Tank Full LED will flash THREE
times indicating you have entered program
mode.
2. Push the WATER SAVER
button. This
will disable/enable this feature.
3. Push the WATER ONLY
button. The
Holding Tank Full LED will flash THREE times
indicating you have left program mode.
Repeat steps 1 to 3 to re-enable these buttons.
Extending pause for water retention:
Some installations may require adjustment if water
siphons out of the bowl after the flush cycle is
complete. This adjustment will increase the pause
time between the final empty time and the water
retention fill time. The factory set pause is for 2
seconds, but can be changed to 10 seconds by fol-
lowing the procedure below:
1. Hold the WATER ONLY
and EMPTY
ONLY
buttons down together for 3
seconds. The Holding Tank Full LED will flash
THREE times indicating you have entered
program mode.
2. Push the WATER SAVER
button. This
will disable/enable the 10 second pause mode.
3. Push the WATER SAVER
button again to
exit program mode. The Holding Tank Full
LED will flash THREE times indicating you
have left program mode.
Repeat steps 1 to 3 to re-enable change between
pause modes.
The Tank LED will flash once indicating a valid
key push. The maximum water retention time is
10 seconds. When finished, push the NORMAL
FLUSH
button to store this value and exit.
The Holding Tank Full LED will flash THREE
times indication you have left program mode.
NOTE:
When in Continuous mode, the WATER
SAVER
empty time will operate at half of the
NORMAL FLUSH
time setting (Wall switch
models only).
L480 0216jlc