Raritan Purasan PST12EX Скачать руководство пользователя страница 7

7

INST

ALLA

TION 

LOCATION AND MOUNTING

Treatment Unit:
WARNING: 

Do not locate in an area where ambient 

temperature exceeds 120

o

 F (49

o

 C)

.

1.  Locate  top  of  treatment  tank  at  or  below 

discharge of toilet and within six feet (1.5 m) 

of toilet. 

Note:

 Longer runs require additional flush time to 

avoid sewage laying in the hose.

Note:

    If  mounting  treatment  tank  higher  than 

discharge, a vented loop must be used between 

toilet and Treatment Unit. 

2.  Make  and  secure  mounting  frame  to  flat 

surface. (FIG 5)

3.  Secure  tank  to  frame  using  3/4”  (1.9  cm) 

mounting straps. 

Note: 

Placing a 3/8” (.9 cm) rubber pad under tank 

will help to reduce vibration and noise. 

Control Module :

Note: Wires supplied are 6 feet between tank and     

  control module

1.   

Locate control module between Tablet Dis

-

penser and Treatment Unit. Vertical mounting is 

recommended (FIG 6) 

2. Using screws secure manifold to the wall (FIG 6)  

Switch Panel: 

Cable Supplied is 16 feet 

1.   Locate in head compartment where indicator 

lights will be visible. 

2.   Using base plate, mark the cutout for the panel. 

(See FIG 7)

3.   Route  cable  between  switch  panel  and 

PURASAN

®

EX 

Control module.

4.   Attach cable to back of switch panel.

5.   After  wiring  and  testing  entire  system:  

Mount panel using 4 screws. Apply a bead of 

nonpermanent sealant around rear edges of 

panel if located in shower area.

PURASAN

®

EX Tablet Dispenser 

 1.  Locate tablet dispenser in a location where  

refill of tablet is convenient. (To easily remove 

lid and refill tablets a clearance of 8” from top 

of lid is recommended.) 

2.  Attach to wall or suitable structure using 1/4” 

(6 mm) bolts.

NOTE:  

Do Not load tablets into Tablet Dispenser 

at this time. Load tablets after completing start 

up procedure.

Size for panel

FIG 7

2 1/4” (57mm)

5/64” (2 MM)

FIG 6

Treatment Unit Mounting

14 1/8”

(35.9cm)

Mounting Frame*

1” (2.5cm)

Mounting 

Straps - not included

INTAKE

DISCHARGE

1” (2.5cm)

7”

(17.8 cm)

Crossover Plug

FIG 5

Control Module

Air pump

Water valve

L519 _0815jlc 

Содержание Purasan PST12EX

Страница 1: ...personnel that may result from improper installation or operation of this product WARNING HAZARD OF SHOCK AND FIRE Always use recommended fuse or circuit breaker and wire size WARNING HAZARD OF FLOOD...

Страница 2: ...ing tank is above the LOW LEVEL treatment cycle starts Macerator pump is activated and moves approximately 1 gallon of waste from the holding tank to the treatment tank Treatment cycles runs for 2 min...

Страница 3: ...cle completes normal there is a 8 second pause before next cycle will start During this pause none of the buttons except No Discharge mode button is functional MAINTENANCE CAUTION Do not load tablets...

Страница 4: ...nstructions in the Owner s Manual for that particular toilet Recommissioning IMPORTANT Do not open shut off valve feeding control module until Treatment Tank is full Do not operate PURASAN EX until Tr...

Страница 5: ...er Size with macerator pump Fuse Specifications 3 1 4 8 3 cm 4 3 4 12 cm SWITCH PANEL DIMENSIONS Depth 8 22 3cm Width 16 40 6cm TREATMENT UNIT DIMENSIONS Height 13 34 3cm TABLET DISPENSER DIMENSIONS F...

Страница 6: ...ubing 6 3 8 ID tubing For Treatment unit 6 3 8 ID tubing Switch Panel Switch Panel Gasket Tablet Dispenser Inside the module Drain Manifold Water Valve SPC control box 6 black and orange wire to conne...

Страница 7: ...e wall FIG 6 Switch Panel Cable Supplied is 16 feet 1 Locate in head compartment where indicator lights will be visible 2 Using base plate mark the cutout for the panel See FIG 7 3 Route cable between...

Страница 8: ...or nonpermanent thread sealing compound on threaded PVC fittings and connections Avoid low areas in hose that would allow untreated waste to collect 1 Connect discharge of macerator to one intake port...

Страница 9: ...le from Tablet Dispenser to Control module Using cable clamp secure cable on the wall near dispenser 2 Connect sensor cable to control module SPC Note Complete programming for Fill and Empty timing be...

Страница 10: ...R NO DISCHARGE TREATMENT RARITAN KEY SWITCH OPTIONAL SEA COCK OPTIONAL SensaLevelTM BLACK WHITE OR RED BLACK WATER SOLENOID AIR PUMP DRAIN MAINIFOLD NEG POS 3 AMP FUSE TO POS TERMINAL BLACK 12AWG RED...

Страница 11: ...conds recorded in step 3 Note maximum is 20 and minimum is 2 Push the START STOP button to store this value the unit will flash three times indicating the time has been set and you have left program m...

Страница 12: ...11 17 18 8 7 2 3 62 1 62 26 25 56 52 51 22 57 48 47 46 45 44 43 40 41 70 71 80 81 85 84 86 82 83 72 27 39 37 38 36 32 54 53 36 31 30 58 41 137W 221351W 12V 221352W 24V 41 100AW 162000WA SPC 59 66 65...

Страница 13: ...shing 2 31 105 O Ring 31 106 10 32x 7 8 Screws 4 31 112 Cover Gasket DRAIN MANIFOLD ASSEMBLY 41 137W 24 41 151A Adapter 1 4 x 1 2 elbow with check valve 27 41 145 Pull Solenoid 28 41 137 Drain Manifol...

Страница 14: ...are programmable Total treatment time is 120 seconds FILL CYCLE HOLD CYCLE EMPTY CYCLE DRAIN MANIFOLD PORTS Fig13 Water in Fill Air in Air to disp Empty To tank CHECK VALVE SYMBOL Location of Compone...

Страница 15: ...tablet dispenser Press empty button to run air pump and clear any clog Clogged Check valve treatment tank adapter Clean or replace check valve 41 170 located on the tank Water fill time not programme...

Страница 16: ...SPECIAL OR CONSE QUENTIALDAMAGES WHETHERARISING OUT OF BREACH OF WARRANTY BREACH OF CONTRACT OR OTHERWISE SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO...

Отзывы: