background image

5

SPECIFICA

TIONS

U.S.C.G. Type I MSD Certification #159.015/0010133/0 (12V) 159.015/0010134/0 (24V)

Maximum Roll/Pitch Angle:  30°
Maximum Temperature Exposure:  120° F (49° C)

Maximum Total Flush Volume:  1.5 gallons/flush (5.7 liters/flush)

Water - fresh, salt or brackish  Approximate Number of cycles per tablet--50
Hold n Treat capacity: 6 gallons (23 liters) per hour , 140 Gallon( 530 Liters) per day

CONVERSIONS

Wire - AWG to mm

2

Feet to Meters

Feet

10

15

20

25

30

40

50

Meter

3.1

4.6

6.1

7.6

9.2

12.2

15.2

AWG

16

14

12

10

8

6

4

2

mm

2

1.5

2.5

4.0

6.0

10.0

16.0

25.0

35.0

NOTES: for Wiring

Recommended Wire and Fuse/Circuit Breaker Size with macerator pump

Fuse Specifications:

3 1/4”

(8.3 cm)

4 3/4”

(12 cm)

SWITCH  PANEL 

DIMENSIONS

Depth:

8 ¾” (22.3cm)

Width:

16” (40.6cm)

TREATMENT   UNIT   DIMENSIONS

Height:

13 ½” 

(34.3cm)

TABLET  DISPENSER 

DIMENSIONS

Fuse  F1 for Motors (12V and 24V) Located in 

the SPC Control Box: 

ATO 10 AMPS, Maxi blade type.

1.  Distances are from source to unit and back to source

2.  Recommended conductor wire minimum AWG (mm) for 3% voltage drop.

3.   Recommended conductor sizes are based on 105

o

C rated insulation. Refer to 

ABYC standards for other insulation ratings.

Units   

Volt

-

age

Circuit 

Breaker/Fuse 

sizes(AMPS)

Amp. 

draw @

nominal  

voltage

Macerator  

amps @

nominal 

voltage

10 

Feet

20 

Feet

30 

Feet

40 

Feet

50 

Feet

12V

30

10

17

8

AWG

6

AWG

6

AWG

6

AWG

4

AWG

24V

20

8

9

14

AWG

12

AWG

10

AWG

10

AWG

8

AWG

CONTROL

MODULE

6

[152]

7

1
4

[184]

11

1
2

[291]

L519 _0815jlc 

Содержание Purasan PST12EX

Страница 1: ...personnel that may result from improper installation or operation of this product WARNING HAZARD OF SHOCK AND FIRE Always use recommended fuse or circuit breaker and wire size WARNING HAZARD OF FLOOD...

Страница 2: ...ing tank is above the LOW LEVEL treatment cycle starts Macerator pump is activated and moves approximately 1 gallon of waste from the holding tank to the treatment tank Treatment cycles runs for 2 min...

Страница 3: ...cle completes normal there is a 8 second pause before next cycle will start During this pause none of the buttons except No Discharge mode button is functional MAINTENANCE CAUTION Do not load tablets...

Страница 4: ...nstructions in the Owner s Manual for that particular toilet Recommissioning IMPORTANT Do not open shut off valve feeding control module until Treatment Tank is full Do not operate PURASAN EX until Tr...

Страница 5: ...er Size with macerator pump Fuse Specifications 3 1 4 8 3 cm 4 3 4 12 cm SWITCH PANEL DIMENSIONS Depth 8 22 3cm Width 16 40 6cm TREATMENT UNIT DIMENSIONS Height 13 34 3cm TABLET DISPENSER DIMENSIONS F...

Страница 6: ...ubing 6 3 8 ID tubing For Treatment unit 6 3 8 ID tubing Switch Panel Switch Panel Gasket Tablet Dispenser Inside the module Drain Manifold Water Valve SPC control box 6 black and orange wire to conne...

Страница 7: ...e wall FIG 6 Switch Panel Cable Supplied is 16 feet 1 Locate in head compartment where indicator lights will be visible 2 Using base plate mark the cutout for the panel See FIG 7 3 Route cable between...

Страница 8: ...or nonpermanent thread sealing compound on threaded PVC fittings and connections Avoid low areas in hose that would allow untreated waste to collect 1 Connect discharge of macerator to one intake port...

Страница 9: ...le from Tablet Dispenser to Control module Using cable clamp secure cable on the wall near dispenser 2 Connect sensor cable to control module SPC Note Complete programming for Fill and Empty timing be...

Страница 10: ...R NO DISCHARGE TREATMENT RARITAN KEY SWITCH OPTIONAL SEA COCK OPTIONAL SensaLevelTM BLACK WHITE OR RED BLACK WATER SOLENOID AIR PUMP DRAIN MAINIFOLD NEG POS 3 AMP FUSE TO POS TERMINAL BLACK 12AWG RED...

Страница 11: ...conds recorded in step 3 Note maximum is 20 and minimum is 2 Push the START STOP button to store this value the unit will flash three times indicating the time has been set and you have left program m...

Страница 12: ...11 17 18 8 7 2 3 62 1 62 26 25 56 52 51 22 57 48 47 46 45 44 43 40 41 70 71 80 81 85 84 86 82 83 72 27 39 37 38 36 32 54 53 36 31 30 58 41 137W 221351W 12V 221352W 24V 41 100AW 162000WA SPC 59 66 65...

Страница 13: ...shing 2 31 105 O Ring 31 106 10 32x 7 8 Screws 4 31 112 Cover Gasket DRAIN MANIFOLD ASSEMBLY 41 137W 24 41 151A Adapter 1 4 x 1 2 elbow with check valve 27 41 145 Pull Solenoid 28 41 137 Drain Manifol...

Страница 14: ...are programmable Total treatment time is 120 seconds FILL CYCLE HOLD CYCLE EMPTY CYCLE DRAIN MANIFOLD PORTS Fig13 Water in Fill Air in Air to disp Empty To tank CHECK VALVE SYMBOL Location of Compone...

Страница 15: ...tablet dispenser Press empty button to run air pump and clear any clog Clogged Check valve treatment tank adapter Clean or replace check valve 41 170 located on the tank Water fill time not programme...

Страница 16: ...SPECIAL OR CONSE QUENTIALDAMAGES WHETHERARISING OUT OF BREACH OF WARRANTY BREACH OF CONTRACT OR OTHERWISE SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO...

Отзывы: