11

INITIAL SETTING OF 

“FILL” and  “EMPTY”

 

Must be completed during installation to be sure water 

reaches level mark on dispenser.

1.   

  All settings should be done with water source (on 

board pressure pump or shore water supply) that 

will be used with PURASAN. Settings done will 

only be valid for that source, and may need to be 

reprogrammed if another source is utilized. Lid 

must be closed tight during setting and use.

2.

   Dispenser must not contain tablets during initial 

set-up. Program “fill” time without tablet to 

reach 1/4” below top marked lines, Unplug sen

-

sor cable at Control Module.

3.   With power on, press “fill “and count seconds 

until water reaches to water level mark on 

dispenser. Record seconds as fill. If recorded 

seconds are greater than 18 , Open the hole to 

approx 1/8” in  metering washer between water 

valve (221352) and check valve (PX50W) and 

repeat.

4.    Empty water below tablet dispenser bottom 

and entire 3/8” tube  till treatment tank while 

pressing “empty” button and counting seconds. 

Record seconds as empty

5. SET PRELIMINARY “FILL” time: 

•  Hold the EMPTY & FILL buttons down together 

for three seconds.  The error  LED will give three 

quick flashes indicating you have entered pro

-

gram mode - release both buttons.

•  Press “FILL “ button as many times as fill 

seconds recorded in step 2. example:  8 seconds 

press 8 times. Note: maximum is 20  and mini

-

mum is 2.

•  Push the “START/STOP” button to store this 

value (the unit will flash three times indicating 

the time has been set and you have left program 

mode).

6. SET PRELIMINARY “EMPTY” time:

 

•  Hold the EMPTY & FILL buttons down together 

for three seconds.  The error  LED will give three 

quick flashes indicating you have entered pro

-

gram mode - release both buttons.

•  Press “EMPTY “ button as many times as empty 

seconds recorded in step 3. Note: maximum is 20 

and minimum is 2. 

•  Push the “START/STOP” button to store this 

value (the unit will flash three times indicating 

the time has been set and you have left program 

mode).

Macerator 

PUMP

FIG 11

FILL

EMPTY

ERROR

Treatment

PROGRAMMING

7. TEST SETTINGS: 

Without tablets: 

Press start/stop button. Water should 

fill up in the dispenser at least up to lower line but no 

higher than half way between line. Hold time of water 

is 20 seconds and not programmable. 

After hold time air pump and drain valve will drain 

solution. Make sure that water is drained from entire 

tube up to treatment tank. Increase empty time using 

step 6 if drain time is not sufficient. After drain cycle, 

air pump and water solenoid will stay on for 10 more 

seconds (non-programmable) to flush check valve 

near tank. Repeat flush cycle to check fill time. If 

water is not filling up to level between lines, increase 

or decrease fill time using steps 2 to 6.

Note: Cycle after drain cycle can be stopped by press

-

ing start/stop button at any time.

With tablets:  

Follow start up procedure. Load tablets 

and plug sensor cable. If wired to start with toilet: 

flush toilet, else press “START/STOP” button, water 

should fill up between level line. Make final adjust

-

ment as per above instructions if needed.

Setting of Transfer/macerator pump on time:

Note: Pump time is set to 10 seconds as shipped.

•  Hold the EMPTY & FILL buttons down together 

for three seconds.  The error  LED will give three 

quick flashes indicating you have entered program 

mode - release both buttons.

•  Press no discharge button (FIG 11)  (next to start 

/stop button)  as many times as needed set pump 

on time.(One push = 1 sec’s,  two = 2 sec’s, 

three= 3 sec’s etc.) The LED will flash once in

-

dicating a valid key push.  Note: Maximum is 20 

seconds. 

•  Push the “START/STOP” button to store this 

value (the unit will flash three times indicating 

the time has been set and you have left program 

mode). 

L519 _0815jlc 

Содержание Purasan PST12EX

Страница 1: ...personnel that may result from improper installation or operation of this product WARNING HAZARD OF SHOCK AND FIRE Always use recommended fuse or circuit breaker and wire size WARNING HAZARD OF FLOOD...

Страница 2: ...ing tank is above the LOW LEVEL treatment cycle starts Macerator pump is activated and moves approximately 1 gallon of waste from the holding tank to the treatment tank Treatment cycles runs for 2 min...

Страница 3: ...cle completes normal there is a 8 second pause before next cycle will start During this pause none of the buttons except No Discharge mode button is functional MAINTENANCE CAUTION Do not load tablets...

Страница 4: ...nstructions in the Owner s Manual for that particular toilet Recommissioning IMPORTANT Do not open shut off valve feeding control module until Treatment Tank is full Do not operate PURASAN EX until Tr...

Страница 5: ...er Size with macerator pump Fuse Specifications 3 1 4 8 3 cm 4 3 4 12 cm SWITCH PANEL DIMENSIONS Depth 8 22 3cm Width 16 40 6cm TREATMENT UNIT DIMENSIONS Height 13 34 3cm TABLET DISPENSER DIMENSIONS F...

Страница 6: ...ubing 6 3 8 ID tubing For Treatment unit 6 3 8 ID tubing Switch Panel Switch Panel Gasket Tablet Dispenser Inside the module Drain Manifold Water Valve SPC control box 6 black and orange wire to conne...

Страница 7: ...e wall FIG 6 Switch Panel Cable Supplied is 16 feet 1 Locate in head compartment where indicator lights will be visible 2 Using base plate mark the cutout for the panel See FIG 7 3 Route cable between...

Страница 8: ...or nonpermanent thread sealing compound on threaded PVC fittings and connections Avoid low areas in hose that would allow untreated waste to collect 1 Connect discharge of macerator to one intake port...

Страница 9: ...le from Tablet Dispenser to Control module Using cable clamp secure cable on the wall near dispenser 2 Connect sensor cable to control module SPC Note Complete programming for Fill and Empty timing be...

Страница 10: ...R NO DISCHARGE TREATMENT RARITAN KEY SWITCH OPTIONAL SEA COCK OPTIONAL SensaLevelTM BLACK WHITE OR RED BLACK WATER SOLENOID AIR PUMP DRAIN MAINIFOLD NEG POS 3 AMP FUSE TO POS TERMINAL BLACK 12AWG RED...

Страница 11: ...conds recorded in step 3 Note maximum is 20 and minimum is 2 Push the START STOP button to store this value the unit will flash three times indicating the time has been set and you have left program m...

Страница 12: ...11 17 18 8 7 2 3 62 1 62 26 25 56 52 51 22 57 48 47 46 45 44 43 40 41 70 71 80 81 85 84 86 82 83 72 27 39 37 38 36 32 54 53 36 31 30 58 41 137W 221351W 12V 221352W 24V 41 100AW 162000WA SPC 59 66 65...

Страница 13: ...shing 2 31 105 O Ring 31 106 10 32x 7 8 Screws 4 31 112 Cover Gasket DRAIN MANIFOLD ASSEMBLY 41 137W 24 41 151A Adapter 1 4 x 1 2 elbow with check valve 27 41 145 Pull Solenoid 28 41 137 Drain Manifol...

Страница 14: ...are programmable Total treatment time is 120 seconds FILL CYCLE HOLD CYCLE EMPTY CYCLE DRAIN MANIFOLD PORTS Fig13 Water in Fill Air in Air to disp Empty To tank CHECK VALVE SYMBOL Location of Compone...

Страница 15: ...tablet dispenser Press empty button to run air pump and clear any clog Clogged Check valve treatment tank adapter Clean or replace check valve 41 170 located on the tank Water fill time not programme...

Страница 16: ...SPECIAL OR CONSE QUENTIALDAMAGES WHETHERARISING OUT OF BREACH OF WARRANTY BREACH OF CONTRACT OR OTHERWISE SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO...

Отзывы: