2
Error/No discharge LED:
Flashing (every 1/4 sec):
Check tablet cartridge
Solid:
Check motor fuse
Flashing(every 4 sec):
No discharge mode
OPERA
TION
SWITCH PANEL
Empty:
Activates Drain
Manifold and Air
Pump momentarily
Fill:
Activates Water Valve and
fills Tablet Dispenser
momentarily
FIG 2
Treatment LED:
Flashing(1/4 sec):
Treatment cycle
Flashing (3 sec):
Treat mode
Both LED flashing:
Tank full level
TABLET DISPENSER
FIG 3
Manual Start/Stop
Disabled for no discharge mode
Press to switch between
Treat and No Discharge
mode
TREAT/NO DISCHARGE MODE;
Press no discharge button on panel once to toggle
mode from treat to no discharge.
If position sensing shutoff valve is installed
close valve to set no discharge mode
Open Valve and press treat/no discharge button on
panel to set treat mode.
If key switch panel is installed, turn key switch to
no discharge to set no discharge mode.
Turn key to treat position and press treat /no dis
-
carge button on panel to set treat mode.
Note: Pause at least 10 seonds after mode is
switched to switch again.
Basic Operation:
When the Hold n’ Treat System is in treatment
mode and level in holding tank is above the LOW
LEVEL, treatment cycle starts. Macerator pump
is activated and moves approximately 1 gallon of
waste from the holding tank to the treatment tank.
Treatment cycles runs for 2 minutes.At the end of
the cycle , system waits in treatment mode for 8
seconds and cycle is repeated until the level in the
tank falls below the LOW LEVEL. If the LOW
LEVEL is not reached after ten cycles, the system
will enter into a COOL DOWN mode for ten min
-
utes. When the system is set to NO DISCHARGE,
waste will enter the holding tank and will not be
treated until set to treatment mode.
PROCESSING LED:
• blinks twice per second when unit is in treatment
cycle.
• blinks every 3 second if unit is in treat mode
and holding tank level is below LOW level or
in between treatment cycle
• blinks twice per seconds with error LED when
holding tank level is above HIGH level.
No discharge LED:
• blinks every 4 seconds when in no discharge
mode
•
blinks twice per seconds when tablet dispenser
needs to checked for tablets or water level.
• on solid when motor fuse is blown
START/STOP BUTTON:
Press start button to
start a cycle during treat mode to process holding
tank below LOW level. DO NOT RUN MAC
-
ERATOR PUMP DRY.
Note: There is 8 seconds pause between cycles.
Overfill
Sensor
Low Tablet
Sensor
Tablet Holder
Water Line
L519 _0815jlc