When you are finished using
Remote Console
, close the browser window.
6.
Repeat the steps in this section to connect to and manage other nodes via in-band KVM
interfaces.
Managing Node Power via an In-Band Power Interface
You can power on, power off, recycle power, or gracefully shutdown a node via an associated in-
band power interface. Graceful shutdown allows the node to complete any processes it is
currently running, while not allowing any new processes to begin, so that the node can shutdown
without interrupting anything.
1.
In the
Nodes
tree, select the node you want to manage through an in-band power interface.
The Node Profile screen appears. The figure below shows an HP iLO/RILOE-enabled node
with an in-band iLO-RILOE power control interface.
Figure 17 Node Profile Screen, In-Band Power Interface
2.
In the Node Profile screen, all configured interfaces display in the Interfaces section.
3.
In the Name column, click the hyperlink of the in-band power interface you want to use to
control power to the node. The
Power Control
screen appears.
Figure 18 Power Control Screen, iLO/RILOE
4.
The selected node’s name displays in the
Node
field.
Содержание CommandCenter CC-SG
Страница 2: ...This page intentionally left blank...
Страница 8: ...This page intentionally left blank...
Страница 10: ...2 COMMANDCENTER SECURE GATEWAY USER GUIDE This page intentionally left blank...
Страница 20: ...12 COMMANDCENTER SECURE GATEWAY USER GUIDE This page intentionally left blank...
Страница 54: ...46 COMMANDCENTER SECURE GATEWAY USER GUIDE This page intentionally left blank...