background image

NINOX 640 SU/USER MANUAL/01-21/REV1.0 

 

 

 

CORPORATE HEADQUARTERS 

Raptor Photonics LTD 
Willowbank Business Park 

Larne, Co Antrim 

BT40 2SF 

Northern Ireland 
PH: +44 2828 270141 

 

www.raptorphotonics.com 

 

Содержание Ninox 640 SU

Страница 1: ...NINOX 640 SU USER MANUAL 01 21 REV1 0 NINOX 640 SU Model NXU CL 640 USER MANUAL...

Страница 2: ...cing 9 6 CAMERA AND CHILLER SETUP 10 6 1 Connecting the Camera to the Frame Grabber 10 6 2 Connecting Camera to Chiller 10 6 3 Recommended Coolants for Chiller 10 6 4 Setting the Coolant Temperature f...

Страница 3: ...NINOX 640 SU USER MANUAL 01 21 REV1 0 9 5 Manufacturers Data 20 10 XCAP CONTROL FEATURES 21 10 1 Saving Preset Configuration Settings 21 10 2 Contrast Modification XCAP Std Only 22...

Страница 4: ...dout noise rms of 30e and a typical dark current reading of 300e p s at 80 C the Ninox 640 SU improves even further on its noise performance Raptor recommends that this manual be used to optimize came...

Страница 5: ...on swab can be used but may leave some fibres on the window so be careful To avoid this you could also use a lens tissue or a cleaning swap such as a texwipe Forced air can be applied to remove any lo...

Страница 6: ...readout noise of 30e The camera has a high intra scene dynamic range for simultaneous capture of light and dark regions of a scene The Camera Link digital interface provides the most stable platform...

Страница 7: ...640 SU USER MANUAL 01 21 REV1 0 4 DESIGN OVERVIEW 4 1 Mechanical Model Units shown in mm and inches in PDF of mechanical model available from our website https www raptorphotonics com products ninox 6...

Страница 8: ...g to a Tripod or Optical Table The camera has a 20 BSW Whitworth threaded hole to mount to a tripod or an optical table 1 3M CameraLink connector Part 12226 1150 00FR 2 Power Connector Part KPJX PM 4S...

Страница 9: ...ional Instruments imaging tools such as NI MAX The file may also be useful if attempting to create your own LabView VI 5 3 Custom Software Interfacing Raptor works closely with EPIX Inc who integrates...

Страница 10: ...r 2 Keep the chiller horizontal and on a level surface 3 Make sure there is a minimum 12 clearance and free path for flow of air entry and exit at the left side and right side of the T257P chiller pri...

Страница 11: ...olant change be implemented at a minimum every six months to keep the system in working order Based on the amount of use you may need to perform this more frequently For more detailed information plea...

Страница 12: ...a x1 PCIe bus and PIXCI EB1 providing roughly 200MB sec maximum bandwidth Contact EPIX Inc for further information regarding minimum computer laptop specification requirements to run the XCAP Imaging...

Страница 13: ...e version with support for the latest cameras and latest PIXCI imaging boards Open the downloaded file when complete and follow the onscreen instructions in the installation wizard If a pop up message...

Страница 14: ...eters set to the default states Open w Last used Video Setup will open the control panel with all parameters set at the last known state Once this option between the two has been selected click Ok To...

Страница 15: ...ntrol panel will have three moving dots This indicates that you are obtaining video data from the camera The imaging statistics displayed directly underneath the imaging window will also inform you if...

Страница 16: ...in Figure 6 High Gain Low Gain Min Exposure Time 15 s 15 s Max Exposure Time Frame Period ms 10 2ms Frame Period ms 10 2ms Exposure Resolution 13 89ns 13 89ns Frame Rate The frame rate can also be se...

Страница 17: ...m the Gain tab on the GUI High gain mode provides the best noise performance and can provide better images for low scene illumination e g night imaging Low gain mode provides the best dynamic range an...

Страница 18: ...efault the camera will be set to internal trigger This mode is indicated by the Live option in the dropdown box The camera can be switched to external trigger mode by selecting the Ext Triggered optio...

Страница 19: ...at this temperature as the camera is tested at this temperature under QC and this is the specification TEC set point of the camera To achieve a sensor temperature of 80 C liquid cooling is required Fo...

Страница 20: ...The Info tab displays the manufacturers data of the camera such as the firmware version and serial number etc The PCB and sensor temperature can be read back from this tab by clicking Update Temp The...

Страница 21: ...ra and frame grabber settings can be saved in the Preset tab under the PIXCI Frame Grabber Model section of the GUI as shown in Figure 16 Up to three different presets can be saved per settings file I...

Страница 22: ...Figure 17 In the contrast modification box that can be seen from Figure 18 select Stretch Contrast Histogram Percentile Endpoints and click preview The contrast modification will now be applied over...

Страница 23: ...NINOX 640 SU USER MANUAL 01 21 REV1 0...

Страница 24: ...NINOX 640 SU USER MANUAL 01 21 REV1 0 CORPORATE HEADQUARTERS Raptor Photonics LTD Willowbank Business Park Larne Co Antrim BT40 2SF Northern Ireland PH 44 2828 270141 www raptorphotonics com...