- 37 -
5.2 Troubleshooting
Carriage does not move upward, corner proximity switch malfunction
Symptom
: Machine corner proximity switch counter problem.
Solution
:
1) Verify corner proximity switch is functioning properly.
2) Adjust the angle of the proximity switch.
After charging for 8 hours, battery charge does not increase (battery is holding a charge).
Symptom
: Battery fails to charge
Solution
:
Verify proper connection of battery charging unit and battery connectors.
After charging for 8 hours, battery charge indicator reads zero (battery is not holding a
charge).
Symptom
: Battery fails to charge / Battery does not hold a charge
Solution
:
Replace batteries