background image

WOOD'S POWR-GRIP

®

 GUIDE TO MAINTENANCE, 

TROUBLESHOOTING AND REPAIR

THE ORIGINAL 

& TRUSTED NAME 

IN VACUUM LIFTING 

EQUIPMENT

Wood's Powr-Grip products are sold 

through authorized dealers. 

800.548.7341

WPG.com

908 West Main - P.O. Box 368

Laurel, Montana 59044 U.S.A.

406.628.8231 (phone)

406.628.8354 (fax)

Based on product information at time of publication. Environmental conditions can affect product performance and longevity;

consult the product instructions on www.WPG.com or contact a Technical Sales Representative for more information.

General Maintenance

Inspect the Hand Cup Regularly:

• Make sure the air filter is in place; if not, discontinue use until the filter is replaced.

• Examine the plunger assembly and handle for dents, cracks or other damage.

• Make sure the face of the vacuum pad feels grippy (not slick). Otherwise, replace the pad.

• Examine the vacuum pad for cuts or roughness on the sealing edge (see Inspect the Sealing Edge below).

• Periodically test the cup for excessive leakage (see Leak-Test the Hand Cup below), sluggishness 

  in plunger action or radical changes in the number of strokes needed to keep the red line hidden.

•  If the cup does not function normally, review the TROUBLESHOOTING GUIDE (overleaf) to determine 

  what corrective action is needed.

Clean the Vacuum Pad:

• Remove the air filter from the pad face.

• Use a clean sponge or lint-free cloth to apply soapy water or another mild cleanser to the pad face. 

 

Never use solvents or rubber conditioners as a cleaning agent

 (see WARNINGS).

• To prevent liquid from contaminating the pump during cleaning, hold the cup facedown 

  or cover the suction inlet in the filter recess.

• Wipe all residue from the pad face and allow the cup to dry.

• Reinstall the air filter.

Inspecting and Testing the Cup for Leakage

Inspect the Sealing Edges:

• Slowly draw your finger along the entire length of the sealing edge, to check for roughness or

  foreign material.

• Examine the sealing edge for cuts by bending the edge of the pad face towards you to create a hump, 

  turning the hand cup as necessary.

• If cuts or cracks are present in a sealing edge, a V-shaped gap will appear.

• Any pad that exhibits a gap or excessive roughness in a sealing edge must be replaced.

Leak-Test the Hand Cup:

•  Attach the cup to a clean, smooth, scratch-free piece of glass or metal for approximately 2 hours.

• The red line on the plunger serves as a vacuum indicator:

  ▪ If the red line 

does not

 appear during the test period, the cup is usable.

  ▪ If the red line 

does

 appear, perform general maintenance and repeat the test.

• If the problem persists, check the TROUBLESHOOTING GUIDE (overleaf) to identify possible causes 

  and appropriate corrective actions.

• If these measures do not restore the cup to normal performance, contact the Wood's Powr-Grip 

  Customer Service department or an authorized dealer for assistance.

LJ6VH(WBP)

VERTICAL HANDLE

AND TL6AG ANGLE 

GRIP HAND CUPS

Rev. 0.5/ 02-22    VH and AG Troubleshooter  

1VHTS 

32625

Содержание LJ6VH

Страница 1: ... apply soapy water or another mild cleanser to the pad face Never use solvents or rubber conditioners as a cleaning agent see WARNINGS To prevent liquid from contaminating the pump during cleaning hold the cup facedown or cover the suction inlet in the filter recess Wipe all residue from the pad face and allow the cup to dry Reinstall the air filter Inspecting and Testing the Cup for Leakage Inspe...

Страница 2: ...d surface Wipe surface clean If necessary wash and allow to dry Contaminated pad face Clean vacuum pad Slick or worn pad face Replace vacuum pad at least once every two years More than 10 strokes needed to apply Any of the above Perform general maintenance Dirt or lubricant on check valve Remove clean and reinstall plunger assembly retainer and check valve as directed in Disassembly and Assembly s...

Страница 3: ... Check Valve and Retainer Carefully examine the inside of the handle for scratches and contaminants using a flashlight Scratches between the midpoint and the closed end of the handle can cause leakage Scratches near the open end of the handle rarely present a problem Make sure that no lubricant remains inside the handle Drop the check valve inside the handle so that it lies flat against the closed...

Страница 4: ...y Do not place the vacuum pad against surfaces which could damage the sealing edge Avoid conditions that could cause the cup to slip or to disengage prematurely such as contaminants cuts or scratches in the pad face or load surface attaching the cup to porous materials or applying pressure against the pad edge Do not use the cup to lift when the red line is visible If the red line reappears freque...

Отзывы: