SECTION 2: INSTALLER RESPONSIBILITY
The installer is responsible for the follo
w
ing:
• To install and commission the air handler, as
w
ell
as the gas and electrical s
u
pplies, in accordance
w
ith applicable specifications and codes. Rapid
Engineering LLC recommends the installer
contact a local b
u
ilding inspector or Fire Marshal
for g
u
idance.
• To
u
se the information gi
v
en in a layo
u
t dra
w
ing
and in the man
u
al together
w
ith the cited codes
and reg
u
lations to perform the installation.
• To install the heater in accordance
w
ith the
clearances to comb
u
stibles.
• To f
u
rnish all needed materials not f
u
rnished as
standard eq
u
ipment.
• To plan location of s
u
pports.
• To pro
v
ide access to air handler for ser
v
icing.
• To pro
v
ide the o
w
ner
w
ith a copy of this
Installation, Operation and Ser
v
ice Man
u
al.
• To ne
v
er
u
se heater as s
u
pport for a ladder or
other access eq
u
ipment and ne
v
er hang or
s
u
spend anything from heater.
• To ens
u
re there is adeq
u
ate air circ
u
lation aro
u
nd
the air handler and to s
u
pply air for comb
u
stion,
v
entilation and distrib
u
tion in accordance
w
ith
local codes.
• To assemble or install any accessories or
associated d
u
ct
w
ork
u
sing best b
u
ilding
practices.
• To properly size s
u
pports and hanging materials.
• To ens
u
re heater is placed in an appro
v
ed
application.
2.1 Wall Tag
A laminated
w
all tag is a
v
ailable for the heater as a
permanent reminder of the safety instr
u
ctions and
the importance of the req
u
ired clearances to
comb
u
stibles. Please contact Rapid Engineering LLC
or yo
u
r RAPID
®
independent distrib
u
tor to obtain the
w
all tag. Affix the tag on a
w
all near the heater (e.g.
thermostat or control system).
A copy of the
w
all tag (P/N 91040118) is ill
u
strated on
the back co
v
er. For an immediate sol
u
tion, yo
u
may
affix this copy on the
w
all near the heater.
Kno
w
yo
u
r model n
u
mber and installed config
u
ration.
Model n
u
mber and installed config
u
ration are fo
u
nd
on the rating plate and in the Installation, Operation
and Ser
v
ice Man
u
al.
2.2 Corrosive Chemicals
Rapid Engineering LLC cannot be responsible for
ens
u
ring that all appropriate safety meas
u
res are
u
ndertaken prior to installation; this is entirely the
responsibility of the installer. It is essential that the
contractor, the s
u
b-contractor, or the o
w
ner identifies
the presence of comb
u
stible materials, corrosi
v
e
chemicals or halogenated hydrocarbons* any
w
here
in the premises.
* Halogena
t
e
d
Hy
d
rocarbons
are a family of chemical
compounds characterized by the presence of halogen elements
(fluorine, chlorine, bromine, etc.). These compounds are
frequently used in refrigerants, cleaning agents, solvents, etc. If
these compounds enter the air supply of the burner, the life span
of the air handler components will be greatly reduced. The loca-
tion of the outside air supply must be carefully chosen to supply
outside air, free of these compounds, to the burners whenever
the presence of these compounds is suspect. Warranty will be
invalid if the air handler is exposed to halogenated hydrocar-
bons.
WARNING
Explosion Hazard
Equipment must have access to
uncontaminated air at all times.
Failure to follow these instructions can result
in death, injury or property damage.
CAUTION
Product Damage Hazard
Do not use equipment in area containing
corrosive chemicals.
Refer to appropriate Material Safety Data
Sheets (MSDS).
Failure to follow these instructions can result
in product damage.