PLEASE READ THE ENTIRE CONTENTS OF THIS MANUAL PRIOR TO 
INSTALLATION AND OPERATION. BY PROCEEDING YOU AGREE THAT 
YOU FULLY UNDERSTAND AND  COMPREHEND THE FULL CONTENTS OF 
THIS MANUAL. FORWARD THIS MANUAL TO ALL OPERATORS. FAILURE TO 
OPERATE THIS EQUIPMENT AS DIRECTED MAY CAUSE INJURY OR DEATH. 

REV A 06-27-16

P/N  5900140         

INSTALLATION AND OPERATION MANUAL

SHIPPING DAMAGE CLAIMS

When this equipment is shipped, title passes to the  

purchaser upon receipt from the carrier. 

Consequently, claims for the material damaged in 

shipment must be made by the purchaser against the  

transportation company at the time shipment is received.

BE SAFE

Ranger™ Evaporative Air Coolers are designed and 

built with safety in mind. However, proper training 

and thoughtful operation on the part of the operator 

can increase your overall safety. DO NOT operate 

or repair this equipment without reading this manual 

and the important safety instructions shown inside.

1645 Lemonwood Dr.

Santa Paula, CA. 93060, USA

Tel: 1-805-933-9970

Toll Free: 1-800-253-2363

Fax: 1-805-933-9160

www.rangerproducts.com

Portable Evaporative Air Cooler

 

Models: 

CB-30L  

110/115 V

CB-30H  

208/220 V

Keep this operation manual near the 

machine at all times. Make sure that 

ALL USERS  read this manual.

Содержание CB-30L

Страница 1: ...pment must be made by the purchaser against the transportation company at the time shipment is received BE SAFE Ranger Evaporative Air Coolers are designed and built with safety in mind However proper...

Страница 2: ...on to return merchandise has been received For all merchandise returned to BendPak Ranger for reasons other than warranty a 20 restocking fee and round trip shipping costs will be deducted from the cr...

Страница 3: ...amaged loose or missing parts Any CB 30L air cooler that appears to be damaged in any way is found to be worn or operated abnormally must be removed from service immediately Any CB 30L evaporative air...

Страница 4: ...mmable liquids or gases 14 Ensure cooler pumps are running continuously to saturate and wet media pads at all times during operation 15 ALWAYS maintain a distance of at least 50 feet from any open fla...

Страница 5: ...mmed control panel with LCD display and comes with a convenient remote control Built in timer allow the unit to be programmed to turn on or off at preselected times A large 30 inch diameter fan operat...

Страница 6: ...Pipe Size inch NPT fitting Back Safety Net Water Distributor Water Pipe Grille Motor Cooler Housing LCD Panel Side Panel Front Net Add Water Back Caster Front Caster Footing Water Tank Diffuser CB 30...

Страница 7: ...e function of setting time Press TIMER 6 Press SWING to move the louvers side to side and help circulate cold air more efficiently 7 ION button Built in ionizer to release negative ions for cleaner ai...

Страница 8: ...e must not exceed the required volt 5 No pollution around the working area B The circuit of the machine must be properly connected and protected to prevent mouse bites Trampled or over stretched which...

Страница 9: ...et Change fan Change master control board Motor is not working Master control is not working Panel is not working Change master control board Change the panel The drain valve leaks water The drain val...

Страница 10: ...y Relay Marboard Signal Switch Capacitors Red Orange White Live Wire AC L Ground Neutral Wire AC N Max Airflow 10595 CFM Power Consumption 550W Style Axial Water Consumption 2 65 3 96 Gal Hr Water Cap...

Страница 11: ...________________________________ ____________________________________________________________________ ____________________________________________________________________ _____________________________...

Страница 12: ...12...

Отзывы: