background image

Data Sheet-3

AD22S

AUDIO DELAY

AD22S Block Diagram 

(both channels identical)

Application Information

DISTANCE MODE

There’s more than one way to view your time setting. If you’re 

tired of looking at milliseconds, the delay setting can also be 

viewed in terms relative to distance by changing the displayed 

units to feet or meters and by selecting the ambient temperature 

in either °C or °F. The AD22S calculates the precise environmen-

tal delay by using the relationship of air pressure and tempera-

ture to the speed of sound.

VIDEO MODE

The AD22S is an effective solution to the problem of aligning 

audio with video in broadcast. Because of the latency involved in 

processing video streams, timing offset accumulates that can run 

as high as several frames or lead to noticeable synchronization 

issues. While in Video mode, the AD22S displays the delay time 

in the precise number of frames calculated for your current for-

mat and frame rate. You may choose from a selection of the most 

common frame rates to match your work situation and environ-

ment. As you adjust the number of frames needed to synchronize 

the audio, the AD22S calculates the delay to match exactly what 

you need.

REMOTE RECALL

In some situations it may be necessary to recall a stored setting 

or enable channel bypass from a location other than where the 

AD22S is located. Have a room divider wall? You can install a 

switch to select between the two room settings automatically 

when the wall is moved. Does the delay for your outdoor speaker 

array change with the temperature? Wire up a switch to change 

from a memory setting adjusted for one temperature to one saved 

for the other when the weather warms up. For these reasons we 

have provided remote recall connections on the rear of the unit 

that can be wired to standard switches installed in any other 

location.

RFI Filter

DSP

MICROCONTROLLER

FRONT PANEL 

CONTROLS

LCD DISPLAY

A/D

Front Panel Lockout

Remote Ch 1 

Remote Ch 2 

Bypass

Recall

Bypass

Recall

Delay

Bypass

GND

GND

GND

D/A

INPUT

OUTPUT

Bypass 

Relay

NONVOLATILE 

MEMORY

DELAY MEMORY

Sig / 

OL

Содержание AD22S

Страница 1: ...et Sound System Interconnection Rane Professional Live Sound Products Warranty Declaration of Conformity 22265 1 88 8 FRAMES 23 976 fps MEM A 2 88 8 FRAMES 24 fps MEM A AD22S AUDIO DELAY DISTANCE ALIGNMENT CURSOR OL SIG VIDEO BYPASS STORE MEMORY RECALL FINE COARSE 1 2 1 2 1 2 CHANNEL CHANNEL 1 CHANNEL 2 LINK ...

Страница 2: ...the power cord is the AC mains disconnect device and must remain readily operable To completely disconnect this apparatus from the AC mains disconnect the power supply cord plug from the AC receptacle 16 This apparatus shall be connected to a mains socket outlet with a protective earthing connection 17 When permanently connected an all pole mains switch with a contact separation of at least 3 mm i...

Страница 3: ...courant alternatif AC et doit absolument rester accessible Pour déconnecter totalement l appareil du secteur débranchez le câble d alimentation de la prise secteur 16 Cet appareil doit être branché à une prise terre avec protection 17 Quand il est branché de manière permanente un disjoncteur tripolaire normalisé doit être incorporé dans l installation électrique de l immeuble 18 En cas de montage ...

Страница 4: ......

Страница 5: ...ion of 0 5 frames to line up perfectly with any video stream WEAR PARTS This product contains no wear parts RANE AD22S AUDIO DELAY AD22S AUDIO DELAY DISTANCE ALIGNMENT CURSOR OL SIG VIDEO BYPASS STORE MEMORY RECALL FINE COARSE 1 2 1 2 1 2 CHANNEL CHANNEL 1 CHANNEL 2 LINK SETTING DELAY Use the CURSOR buttons to select the unit type then press the COARSE or FINE buttons to cycle through options In D...

Страница 6: ...rrent memory for the selected channel If the asterisk character is shown to the right of the display the current value does not match the memory location 8 RECALL button Copies the stored delay setting into the active channel If channels are linked then both are recalled 9 BYPASS buttons Toggle relays for each channel If LED is on bypass is enabled and the device functions like a wire If bypass LE...

Страница 7: ...s in the future This port provides no other functions and should not be connected during normal use See the FIRMWARE UPDATE section on the next page 6 UNIVERSAL POWER SUPPLY Universal IEC power jack connects anywhere in the world to AC line voltage 100 240 VAC 50 60 Hz 2 3 4 5 6 1 CH 1 INPUT CH 2 INPUT CH 1 OUTPUT CH 2 OUTPUT CH 1 REMOTE CH 2 REMOTE FRONT PANEL CONTROL LOCKS USB FIRMWARE UPDATE PI...

Страница 8: ...tly to the outputs This makes it easy to set up and verify that signals are present before turning on any delay The yellow bypass indica tors mean that BYPASS is active press each BYPASS button to disable ALIGNMENT MODE Two modes of operation are available If working with video and wish to set delay by number of frames press VIDEO for video alignment Otherwise press DISTANCE for distance alignment...

Страница 9: ...ettings are always saved into working memory and restored upon power up Rear terminals let you connect standard switches to recall settings remotely The AD22S s balanced XLR inputs and outputs offer the Rane standard of audio quality with 24 bit processing and delay precision down to 0 01 ms With the ability to provide unity gain up to a maximum input level of 24 dBu the unit can be used with stan...

Страница 10: ...ss on power loss LED Thresholds Clip 3 before converter overload 1 dB 22 dBu 1 kHz Signal Present 47 below Clip LED 1 dB 25 dBu 1 kHz Frequency Response 20 Hz 22 kHz 0 3 dB 4 dBu 20 Hz to 20 kHz System Gain High Impedance Load 0 0 5 dB Load 10 0 kΩ balanced 4 dBu 20 Hz to 22 kHz 600 Ω Load 0 0 1 dB Load 600 Ω balanced 4 dBu 20 Hz to 22 kHz THD Noise 0 006 0 002 4 dBu 20 Hz to 20 kHz 30 kHz BW Sign...

Страница 11: ... rate You may choose from a selection of the most common frame rates to match your work situation and environ ment As you adjust the number of frames needed to synchronize the audio the AD22S calculates the delay to match exactly what you need REMOTE RECALL In some situations it may be necessary to recall a stored setting or enable channel bypass from a location other than where the AD22S is locat...

Страница 12: ...all common NTSC and PAL SECAM frame rates A 40x2 backlit character LCD shall indicate current delay settings and provide cursor controls for selecting and setting the delay values and configuration parameters including tempera ture frame rate and stored memory values Bypass status signal overload presence and mode of operation shall be indicated with individual indicators Terminals on the rear pan...

Страница 13: ...connections Grounding and EMC practices Shields of connectors in audio equipment containing active circuitry Rane s policy is to accommodate rather than dictate However this document contains suggestions for external wiring changes that should ideally only be implemented by trained technical personnel Safety regulations require that all original grounding means provided from the factory be left in...

Страница 14: ...rconnect is not compat ible with unbalanced The small physical nature and short cable runs of completely unbalanced systems home audio also contain these ground loop noise currents However the currents in unbalanced systems never get large enough to affect the audio to the point where it is a nuisance Mixing balanced and unbalanced equipment however is an entirely different story since balanced an...

Страница 15: ...ACTICE RECOMMENDED PRACTICE OPTIONAL CASE 1 2 3 3 1 2 CHASSIS GROUND SIGNAL GROUND CHASSIS GROUND CHASSIS GROUND The Next Best Right Way To Do It The quickest quietest and most foolproof method to con nect balanced and unbalanced is to transformer isolate all unbalanced connections See Figure 2 Many manufacturers provide several tools for this task including Rane Consult your audio dealer to explo...

Страница 16: ...rounded and therefore immune to ground loop hums and buzzes Ground lifts are simply another Band Aid to try in case of grounding problems It is true that an entire system of properly grounded equipment without ground lift switches is guaranteed yes guaranteed to be hum free The problem is most equipment is not both internally and externally AC system wise grounded properly Most units with ground l...

Страница 17: ...o guarantee that a hum free intercon nect can be achieved nor is there a definite scheme that will assure noise free operation in all configurations References 1 Neil A Muncy Noise Susceptibility in Analog and Digi tal Signal Processing Systems presented at the 97th AES Convention of Audio Engineering Society in San Fran cisco CA Nov 1994 2 Grounding Shielding and Interconnections in Analog Digita...

Страница 18: ... 20 24 24 19 18 17 B B B B A A A A A A FEMALE BALANCED XLR NOT A TRANSFORMER NOR A CROSS COUPLED OUTPUT STAGE FEMALE BALANCED XLR EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE BALANCED TRS NOT A TRANSFORMER NOR A CROSS COUPLED OUTPUT STAGE BALANCED TRS EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE FLOATING UNBALANCED TRS TIP RING SLEEVE SLEEVE IN UNIT NC OR 3 5 mm UNBALANCED TS TIP S...

Страница 19: ... RED SHIELD RED SHIELD SHIELD RED RED BLACK N C N C N C RED BLACK RED SHIELD N C BLACK RED BLACK RED 3 NC 2 RED 1 SHIELD 2 RED 1 SHIELD 3 BLACK 2 RED 1 NC 3 BLACK 2 RED 1 NC 3 BLACK 2 RED 1 SHIELD SHIELD FEMALE FEMALE FEMALE RED SHIELD RED BLACK SHIELD SHIELD RED BLACK RED BLACK BLACK RED RED SHIELD RED SHIELD RED SHIELD RED SHIELD RED BLACK 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 2 ...

Страница 20: ...D 3 BLACK 2 RED 1 SHIELD 3 BLACK 2 RED 1 SHIELD SHIELD BLACK SHIELD RED BLACK SHIELD RED BLACK RED SHIELD SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD RED SHIELD RED SHIELD RED SHIELD RED BLACK RED N C N C BLACK RED BLACK RED BLACK RED RED SHIELD RED SHIELD RED SHIELD RED 24 S BLACK T RED CROSS COUPLED OUTPUT ONLY CONNECT BLACK TO SHIELD AT THIS END A...

Страница 21: ... WARRANTY SHALL BE THAT WHICH IS DESCRIBED TO THE ORIGINAL RETAIL PURCHASER BY THE AUTHORIZED RANE DEALER OR DISTRIBUTOR AT THE TIME OF PURCHASE Rane Corporation does not however warrant its products against any and all defects 1 arising out of materials or workmanship not provided or furnished by Rane or 2 resulting from abnormal use of the product or use in violation of instructions or 3 in prod...

Страница 22: ...E FACTORY IN THE U S If the product is being sent to Rane for repair please call the factory for a Return Authorization number We recommend advance notice be given to the repair facility to avoid possible needless shipment in case the problem can be solved over the phone UNAUTHORIZED SERVICE PERFORMED ON ANY RANE PRODUCT WILL VOID ITS EXISTING FACTORY WARRANTY FACTORY SERVICE If you wish your Rane...

Страница 23: ...tive and EMC directive in the event that the equipment is modified without written consent of the manufacturer This declaration of conformity is issued under the sole responsibility of Rane Corporation Type of Equipment Professional Audio Signal Processing Brand Rane Model AD22S Immunity Results THD N 4 dBu 400 Hz BW 20 Hz 20 kHz Test Description Specification Conditions RF Electromagnetic Fields ...

Страница 24: ... PANEL CONTROL LOCKS USB FIRMWARE UPDATE PIN 2 POSITIVE PIN 3 NEGATIVE PIN 1 CHASSIS GND 100 240 V 50 60 Hz 7 WATTS RECALL BYPASS RECALL BYPASS DELAY BYPASS CH REMOTE WIRING OPEN RECALLS A CLOSED RECALLS B CLOSED BYPASS CH CLASS 2 WIRING AD22S RANE CORPORATION COMMERCIAL AUDIO EQUIPMENT 24TJ R ...

Отзывы: