Interconnection-4

a small capacitor (0.1 or 0.01 microfarad ceramic disc) con-

nected from the lifted end of the shield to the chassis. (This 

is referred to as the “hybrid shield termination” where the 

sending end is bonded to the chassis and the receiving end is 

capacitively coupled. See Neutrik’s EMC-XLR for example.) 

The fact that many modern day installers still follow this 

one-end-only rule with consistent success indicates this 

and other acceptable solutions to RF issues exist, though 

the increasing use of digital and wireless technology greatly 

increases the possibility of future RF problems.

If you’ve truly isolated your hum problem to a specific 

unit, chances are, even though the documentation indicates 

proper chassis grounded shields, the suspect unit is not in-

ternally grounded properly. Here is where special test cable 

assemblies, shown in Figure 3, really come in handy. These 

assemblies allow you to connect the shield to chassis ground

 

at the point of entry

, or to pin 1, or to lift one end of the 

shield. The task becomes more difficult when the unit you’ve 

isolated has multiple inputs and outputs. On a suspect unit 

with multiple cables, try various configurations on each con-

nection to find out if special cable assemblies are needed at 

more than one point.

See Figure 4 for suggested cable assemblies for your par-

ticular interconnection needs. Find the appropriate output 

configuration (down the left side) and then match this with 

the correct input configuration (across the top of the page.) 

Then refer to the following pages for a recommended wiring 

diagram.

Ground Lifts

Many units come equipped with ground lift switches. In 

only a few cases can it be shown that a ground lift switch 

improves ground related noise. (Has a ground lift switch 

ever 

really

 worked for you?) In reality, the presence of a 

ground lift switch greatly reduces a unit’s ability to be 

“properly” grounded and therefore immune to ground loop 

hums and buzzes. Ground lifts are simply another Band-Aid

®

 

to try in case of grounding problems. It is true that an entire 

system of properly grounded equipment, without ground 

lift switches, is guaranteed (yes 

guaranteed

) to be hum free. 

The problem is most equipment is 

not

 (both internally and 

externally, AC system wise) grounded properly.

Most units with ground lifts are shipped so the unit is 

“grounded” — meaning the chassis is connected to audio 

signal ground. (This should be the best and is the “safest” 

position for a ground lift switch.) If after hooking up your 

system it exhibits excessive hum or buzzing, there is an 

incompatibility somewhere in the system’s grounding con-

figuration.  In addition to these special cable assemblies that 

may help, here are some more things to try:

1. Try combinations of lifting grounds on units supplied 

with lift switches (or links). It is wise to do this with the 

power off!

2. If you have an entirely balanced system, verify all chassis 

are tied to a good earth ground, for safety’s sake and hum 

protection. Completely unbalanced systems never earth 

ground anything (except cable TV, often a ground loop 

source). If you have a mixed balanced and unbalanced 

system, do yourself a favor and use isolation transform-

ers or, if you can’t do that, try the special cable assemblies 

described here and expect it to take many hours to get 

things quiet. May the Force be with you.

3. Balanced units with outboard power supplies (wall warts 

or “bumps” in the line cord) do 

not

 ground the chassis 

through the line cord. Make sure such units are solidly 

grounded by tying the chassis to an earth ground using a 

star washer for a reliable contact. (Rane always provides 

this chassis point as an external screw with a toothed 

washer.) Any device with a 3-prong AC plug, such as an 

amplifier, may serve as an earth ground point. Rack rails 

may or may not serve this purpose depending on screw 

locations and paint jobs.

Figure 3. Test cable

TEST

WIRE

GROUND CLIP

FEMALE

MALE

1

C

2

3

1

2
3

RED

BLACK

SHIELD

RED

BLACK

SHIELD

2-CONDUCTOR SHIELDED CABLE

Содержание AD22S

Страница 1: ...et Sound System Interconnection Rane Professional Live Sound Products Warranty Declaration of Conformity 22265 1 88 8 FRAMES 23 976 fps MEM A 2 88 8 FRAMES 24 fps MEM A AD22S AUDIO DELAY DISTANCE ALIGNMENT CURSOR OL SIG VIDEO BYPASS STORE MEMORY RECALL FINE COARSE 1 2 1 2 1 2 CHANNEL CHANNEL 1 CHANNEL 2 LINK ...

Страница 2: ...the power cord is the AC mains disconnect device and must remain readily operable To completely disconnect this apparatus from the AC mains disconnect the power supply cord plug from the AC receptacle 16 This apparatus shall be connected to a mains socket outlet with a protective earthing connection 17 When permanently connected an all pole mains switch with a contact separation of at least 3 mm i...

Страница 3: ...courant alternatif AC et doit absolument rester accessible Pour déconnecter totalement l appareil du secteur débranchez le câble d alimentation de la prise secteur 16 Cet appareil doit être branché à une prise terre avec protection 17 Quand il est branché de manière permanente un disjoncteur tripolaire normalisé doit être incorporé dans l installation électrique de l immeuble 18 En cas de montage ...

Страница 4: ......

Страница 5: ...ion of 0 5 frames to line up perfectly with any video stream WEAR PARTS This product contains no wear parts RANE AD22S AUDIO DELAY AD22S AUDIO DELAY DISTANCE ALIGNMENT CURSOR OL SIG VIDEO BYPASS STORE MEMORY RECALL FINE COARSE 1 2 1 2 1 2 CHANNEL CHANNEL 1 CHANNEL 2 LINK SETTING DELAY Use the CURSOR buttons to select the unit type then press the COARSE or FINE buttons to cycle through options In D...

Страница 6: ...rrent memory for the selected channel If the asterisk character is shown to the right of the display the current value does not match the memory location 8 RECALL button Copies the stored delay setting into the active channel If channels are linked then both are recalled 9 BYPASS buttons Toggle relays for each channel If LED is on bypass is enabled and the device functions like a wire If bypass LE...

Страница 7: ...s in the future This port provides no other functions and should not be connected during normal use See the FIRMWARE UPDATE section on the next page 6 UNIVERSAL POWER SUPPLY Universal IEC power jack connects anywhere in the world to AC line voltage 100 240 VAC 50 60 Hz 2 3 4 5 6 1 CH 1 INPUT CH 2 INPUT CH 1 OUTPUT CH 2 OUTPUT CH 1 REMOTE CH 2 REMOTE FRONT PANEL CONTROL LOCKS USB FIRMWARE UPDATE PI...

Страница 8: ...tly to the outputs This makes it easy to set up and verify that signals are present before turning on any delay The yellow bypass indica tors mean that BYPASS is active press each BYPASS button to disable ALIGNMENT MODE Two modes of operation are available If working with video and wish to set delay by number of frames press VIDEO for video alignment Otherwise press DISTANCE for distance alignment...

Страница 9: ...ettings are always saved into working memory and restored upon power up Rear terminals let you connect standard switches to recall settings remotely The AD22S s balanced XLR inputs and outputs offer the Rane standard of audio quality with 24 bit processing and delay precision down to 0 01 ms With the ability to provide unity gain up to a maximum input level of 24 dBu the unit can be used with stan...

Страница 10: ...ss on power loss LED Thresholds Clip 3 before converter overload 1 dB 22 dBu 1 kHz Signal Present 47 below Clip LED 1 dB 25 dBu 1 kHz Frequency Response 20 Hz 22 kHz 0 3 dB 4 dBu 20 Hz to 20 kHz System Gain High Impedance Load 0 0 5 dB Load 10 0 kΩ balanced 4 dBu 20 Hz to 22 kHz 600 Ω Load 0 0 1 dB Load 600 Ω balanced 4 dBu 20 Hz to 22 kHz THD Noise 0 006 0 002 4 dBu 20 Hz to 20 kHz 30 kHz BW Sign...

Страница 11: ... rate You may choose from a selection of the most common frame rates to match your work situation and environ ment As you adjust the number of frames needed to synchronize the audio the AD22S calculates the delay to match exactly what you need REMOTE RECALL In some situations it may be necessary to recall a stored setting or enable channel bypass from a location other than where the AD22S is locat...

Страница 12: ...all common NTSC and PAL SECAM frame rates A 40x2 backlit character LCD shall indicate current delay settings and provide cursor controls for selecting and setting the delay values and configuration parameters including tempera ture frame rate and stored memory values Bypass status signal overload presence and mode of operation shall be indicated with individual indicators Terminals on the rear pan...

Страница 13: ...connections Grounding and EMC practices Shields of connectors in audio equipment containing active circuitry Rane s policy is to accommodate rather than dictate However this document contains suggestions for external wiring changes that should ideally only be implemented by trained technical personnel Safety regulations require that all original grounding means provided from the factory be left in...

Страница 14: ...rconnect is not compat ible with unbalanced The small physical nature and short cable runs of completely unbalanced systems home audio also contain these ground loop noise currents However the currents in unbalanced systems never get large enough to affect the audio to the point where it is a nuisance Mixing balanced and unbalanced equipment however is an entirely different story since balanced an...

Страница 15: ...ACTICE RECOMMENDED PRACTICE OPTIONAL CASE 1 2 3 3 1 2 CHASSIS GROUND SIGNAL GROUND CHASSIS GROUND CHASSIS GROUND The Next Best Right Way To Do It The quickest quietest and most foolproof method to con nect balanced and unbalanced is to transformer isolate all unbalanced connections See Figure 2 Many manufacturers provide several tools for this task including Rane Consult your audio dealer to explo...

Страница 16: ...rounded and therefore immune to ground loop hums and buzzes Ground lifts are simply another Band Aid to try in case of grounding problems It is true that an entire system of properly grounded equipment without ground lift switches is guaranteed yes guaranteed to be hum free The problem is most equipment is not both internally and externally AC system wise grounded properly Most units with ground l...

Страница 17: ...o guarantee that a hum free intercon nect can be achieved nor is there a definite scheme that will assure noise free operation in all configurations References 1 Neil A Muncy Noise Susceptibility in Analog and Digi tal Signal Processing Systems presented at the 97th AES Convention of Audio Engineering Society in San Fran cisco CA Nov 1994 2 Grounding Shielding and Interconnections in Analog Digita...

Страница 18: ... 20 24 24 19 18 17 B B B B A A A A A A FEMALE BALANCED XLR NOT A TRANSFORMER NOR A CROSS COUPLED OUTPUT STAGE FEMALE BALANCED XLR EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE BALANCED TRS NOT A TRANSFORMER NOR A CROSS COUPLED OUTPUT STAGE BALANCED TRS EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE FLOATING UNBALANCED TRS TIP RING SLEEVE SLEEVE IN UNIT NC OR 3 5 mm UNBALANCED TS TIP S...

Страница 19: ... RED SHIELD RED SHIELD SHIELD RED RED BLACK N C N C N C RED BLACK RED SHIELD N C BLACK RED BLACK RED 3 NC 2 RED 1 SHIELD 2 RED 1 SHIELD 3 BLACK 2 RED 1 NC 3 BLACK 2 RED 1 NC 3 BLACK 2 RED 1 SHIELD SHIELD FEMALE FEMALE FEMALE RED SHIELD RED BLACK SHIELD SHIELD RED BLACK RED BLACK BLACK RED RED SHIELD RED SHIELD RED SHIELD RED SHIELD RED BLACK 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 2 ...

Страница 20: ...D 3 BLACK 2 RED 1 SHIELD 3 BLACK 2 RED 1 SHIELD SHIELD BLACK SHIELD RED BLACK SHIELD RED BLACK RED SHIELD SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD RED SHIELD RED SHIELD RED SHIELD RED BLACK RED N C N C BLACK RED BLACK RED BLACK RED RED SHIELD RED SHIELD RED SHIELD RED 24 S BLACK T RED CROSS COUPLED OUTPUT ONLY CONNECT BLACK TO SHIELD AT THIS END A...

Страница 21: ... WARRANTY SHALL BE THAT WHICH IS DESCRIBED TO THE ORIGINAL RETAIL PURCHASER BY THE AUTHORIZED RANE DEALER OR DISTRIBUTOR AT THE TIME OF PURCHASE Rane Corporation does not however warrant its products against any and all defects 1 arising out of materials or workmanship not provided or furnished by Rane or 2 resulting from abnormal use of the product or use in violation of instructions or 3 in prod...

Страница 22: ...E FACTORY IN THE U S If the product is being sent to Rane for repair please call the factory for a Return Authorization number We recommend advance notice be given to the repair facility to avoid possible needless shipment in case the problem can be solved over the phone UNAUTHORIZED SERVICE PERFORMED ON ANY RANE PRODUCT WILL VOID ITS EXISTING FACTORY WARRANTY FACTORY SERVICE If you wish your Rane...

Страница 23: ...tive and EMC directive in the event that the equipment is modified without written consent of the manufacturer This declaration of conformity is issued under the sole responsibility of Rane Corporation Type of Equipment Professional Audio Signal Processing Brand Rane Model AD22S Immunity Results THD N 4 dBu 400 Hz BW 20 Hz 20 kHz Test Description Specification Conditions RF Electromagnetic Fields ...

Страница 24: ... PANEL CONTROL LOCKS USB FIRMWARE UPDATE PIN 2 POSITIVE PIN 3 NEGATIVE PIN 1 CHASSIS GND 100 240 V 50 60 Hz 7 WATTS RECALL BYPASS RECALL BYPASS DELAY BYPASS CH REMOTE WIRING OPEN RECALLS A CLOSED RECALLS B CLOSED BYPASS CH CLASS 2 WIRING AD22S RANE CORPORATION COMMERCIAL AUDIO EQUIPMENT 24TJ R ...

Отзывы: