LIST
Turns on spurious emission measurements.
*RST:
AUTO
Example:
SWE:MODE ESP
14.5.7.3
Configuring a Multi-SEM Measurement
In the Spectrum application only, spectrum emissions can be measured for multiple
sub blocks of channels (see
Chapter 7.6.4.5, "SEM with Multiple Sub Blocks ("Multi-
on page 246). Up to 8 sub blocks (with 7 gaps) can be defined. For each sub
block, the familiar configuration settings concerning ranges, limit lines etc. can be
defined in individual tabs (select the sub block using the <sb> suffix in the correspond-
ing commands). In addition, settings on the sub blocks themselves must be configured.
Useful commands for multi-SEM measurements described elsewhere:
●
[SENSe:]ESPectrum<sb>:RANGe<ri>:MLCalc
Remote commands exclusive to multi-SEM measurements
..................................................................................920
...................................................................................920
[SENSe:]ESPectrum<sb>:SCENter
<Frequency>
This command defines the center frequency of the selected sub block in a Multi-SEM
measurement.
Suffix:
<sb>
.
1 to 8
Sub block in a Multi-SEM measurement
Parameters:
<Frequency>
Frequency within the currently defined global span (see
Range:
1 to 3
*RST:
1
Default unit: Hz
Example:
ESP1:SCEN 1GHZ
Manual operation:
See
[SENSe:]ESPectrum<sb>:SCOunt
<Subblocks>
This command defines the number of sub blocks in the SEM measurement.
Suffix:
<sb>
.
irrelevant