Remote Commands
R&S
®
FSW
1024
User Manual 1173.9411.02 ─ 43
14.7.1
Defining the Frequency and Span
The commands required to configure the frequency and span settings in a remote envi-
ronment are described here. The tasks for manual operation are described in
ter 8.3, "Frequency and Span Configuration"
........................................................................... 1024
................................................................................ 1028
14.7.1.1
Defining the Frequency Range
The following commands are required to define the frequency range.
CALCulate<n>:MARKer<m>:FUNCtion:CENTer
.............................................................. 1024
CALCulate<n>:MARKer<m>:FUNCtion:CSTep
................................................................1024
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:X:SPACing
..................................... 1025
....................................................................................... 1025
..............................................................................1025
[SENSe:]FREQuency:CENTer:STEP:AUTO
....................................................................1026
[SENSe:]FREQuency:CENTer:STEP:LINK
......................................................................1026
[SENSe:]FREQuency:CENTer:STEP:LINK:FACTor
..........................................................1027
....................................................................................... 1027
..........................................................................................1027
................................................................................. 1028
......................................................................................... 1028
..........................................................................................1028
CALCulate<n>:MARKer<m>:FUNCtion:CENTer
This command matches the center frequency to the frequency of a marker.
If you use the command in combination with a delta marker, that delta marker is turned
into a normal marker.
Suffix:
<n>
.
<m>
Example:
CALC:MARK2:FUNC:CENT
Sets the center frequency to the frequency of marker 2.
Manual operation:
See
"Center Frequency = Marker Frequency"
CALCulate<n>:MARKer<m>:FUNCtion:CSTep
This command matches the center frequency step size to the current marker fre-
quency.
The command turns delta markers into normal markers.
Suffix:
<n>
.
<m>
Setting Basic Measurement Parameters