Common Measurement Settings
R&S
®
FSW
441
User Manual 1173.9411.02 ─ 43
8.3
Frequency and Span Configuration
The frequency and span settings define the scope of the signal and spectrum to be
analyzed with the R&S
FSW.
Impact of the Frequency and Span Settings
.........................................................441
...............................................................................443
Keeping the Center Frequency Stable - Signal Tracking
...................................... 446
How To Define the Frequency Range
................................................................... 447
How to Move the Center Frequency through the Frequency Range
8.3.1
Impact of the Frequency and Span Settings
Some background knowledge on the impact of the described settings is provided here
for a better understanding of the required configuration.
Defining the Scope of the Measurement - Frequency Range
...............................441
Stepping Through the Frequency Range - Center Frequency Stepsize
Coping with Large Frequency Ranges - Logarithmic Scaling
............................... 442
8.3.1.1
Defining the Scope of the Measurement - Frequency Range
The frequency range defines the scope of the signal and spectrum to be analyzed. It
can either be defined as a span around a center frequency, or as a range from a start
to a stop frequency. Furthermore, the full span comprising the entire possible fre-
quency range can be selected, or a zero span. The full span option allows you to per-
form an overview measurement over the entire span. Using the "Last Span" function
you can easily switch back to the detailed measurement of a specific frequency range.
For sinusoidal signals, the center frequency can be defined automatically by the
R&S
FSW as the highest frequency level in the frequency span (see
Center Frequency Automatically (Auto Frequency)"
8.3.1.2
Stepping Through the Frequency Range - Center Frequency Stepsize
Using the arrow keys you can move the center frequency in discrete steps through the
available frequency range. The step size by which the center frequency is increased or
decreased is defined by the "Center Frequency Stepsize".
The "Center Frequency Stepsize" also defines the step size by which the value is
increased or decreased when you use the rotary knob to change the center frequency;
however, the
rotary knob
moves in steps of only
1/10 of the "Center Frequency
Stepsize"
to allow for a more precise setting.
By default, the step size is set in relation to the selected span or resolution bandwidth
(for zero span measurements). In some cases, however, it may be useful to set the
step size to other values.