OFFSet
Sorts spurs according to their offset from the carrier.
*RST:
POWer
Example:
//Select spur sort order
SPUR:SORT POW
Manual operation:
See
[SENSe:]SPURs:WEIGhting
<Weightingfilter>
This command selects a spurious weighting filter.
Setting parameters:
<Weightingfilter>
Example:
//Select no defined weighting filter
SENS:SPUR:WEIG NONE
Manual operation:
See
"Applying a spurious weighting filter"
[SENSe:]SPURs:FILTer:MODE
<Mode>
This command defines the spurious filter mode
Parameters:
<Mode>
OFF | SUPPress | SHOW
OFF
No spurious filter is applied.
SUPPress
The spurs in the spurious filter are removed from the spurious
list, the diagram and dependent calculations.
SHOW
Only the spurs in the spurious filter are displayed in the spurious
list, the diagram and dependent calculations.
Example:
SENS:SPUR:FILT:MOD OFF
Manual operation:
See
[SENSe:]SPURs:FILTer:HARMonics
<State>
This command defines if harmonics are included in the spurious filter.
Parameters:
<State>
Example:
//Exclude harmonics from the spurious filter
SENS:SPUR:FILT:HARM OFF
Manual operation:
See
Common Measurement Settings