Code
Alarm
Possible cause
Suggested solution
83
Slack wire
Slack wire function
active.
86
Load not calibrated
Load calibration has
not been done.
Perform
load
calibration function.
87
Programmable
limit
active
Programmable limit is
disabling
driving
in
either direction
• Run other direction
• Set the
programmable limit to
other position
• Limit can be also by-
passed temporarily
by activating the
movement control
more than 5 seconds
88
CCU fault
Controlled
common
use fault.
Another device that is
connected in CAN bus
has an active fault.
93
CCU activation
Controlled
common
use activation.
Another device that is
connected in CAN bus
has
caused
the
stopping.