R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
21/21
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
8 TECHNICAL DATA
Mains connection
Supply voltage U
in
380 - 480V, -10%...+10% 3-phase
Supply voltage frequency
45…66 Hz
Connection to mains
Once per minute or less (normal case)
Motor connection
Output voltage
0 — U
in
Nominal output current
003: I
N
5.6A (max 8.4A), 006: I
N
5.6A (max 8.4A), 012: I
N
12A (max 18A)
Continuous output current
Rated current I
n
at ambient temperature max +50
o
C, overload 1.5 x I
N
max
(1min/10min)
Starting current
2 x I
N
2 sec every 20 sec
Output frequency
0…250 Hz (limited options)
Digital inputs
Control voltage
42 – 240 V
ac
, current consumption 14 - 20 mA
Control features
Control method
Frequency Control U/f
Open Loop Sensorless Vector Control
Switching frequency
3,6 kHz
Field weakening point
Adjustable with parameter
Acceleration time
0…20s (0,1s steps)
Deceleration time
0…20s (0,1s steps)
Ambient conditions
Ambient operating temperature
–10°C (no frost)…+50° C (outside the c 40˚C)
Storage temperature
–40°C…+70°C
Relative humidity
0…95% RH, non-condensing, non-corrosive, no dripping water
Air quality:
- Chemical vapors
- Mechanical particles
IEC 721-3-3, unit in operation, class 3C2
IEC 721-3-3, unit in operation, class 3S2
Altitude
100% load capacity (no derating) up to 1000m. 1% derating for each 100m
above 1000m; max. 2000m
Vibration:
EN50178/EN60068-2-6
5...150 Hz
Displacement amplitude 1 (peak) mm at 5...15.8 Hz
Max acceleration amplitude 1 G at 15.8...150 Hz
Shock
EN50178, IEC 68-2-27
UPS Drop Test (for applicable UPS weights)
Storage and shipping: max 15 G, 11 ms (in package)
Enclosure class
IP20
Weight
003 model: 0.9 kg, 006 model: 1.2 kg, 012 model: 1.7 kg
Safety
61800-5-1 (2007), EN60204-1 (2009), CE, UL, cUL, FI, GOST R, IEC (see
the unit’s main sticker for more detailed approvals), RoHS
Protections
Over voltage protection
875V
DC
trip level
Under voltage protection
333V
DC
trip level
Earth-fault protection
Earth fault is tested before every start. In case of earth fault in motor or
motor cable, only the frequency converter is protected.
Unit over temperature
Yes
Motor stall
Yes
Overcurrent protection
Trip limit 4,0*I
N
instantaneously
Motor overtemperature supervision
Yes