1. Read all the SAFETY INSTRUCTIONS before using the product.
2. This product must be earthed. If it should malfunction or break down, grounding provides a path of least 

resistance for electric current to reduce risk of electric shock.
This product is equipped with a cord having an equipment-grounding conductor and a grounding  plug;
The plug must be plugged into an appropriate outlet that is properly installed and earthed in accordance 
with all local   codes and ordinance.

DANGER

Improper connection of the equipment-grounding conductor can result in a risk of electric 

shock.

3.  Do  not  use  this  product  near  water  -  for  example,  near  a  bathtub,  washbowl,  kitchen  sink,  in  wet 

basement or near a swimming poor or the like.

4.  This  product  should  be  located  away  from  heat  sources  such  as  radiators,  heat  registers  or  other 

products that produce heat.

5.  The  product  should  be  connected  to  a  power  supply  only  of  the  type  described  on  the  operating 

instructions or as marked on the product.

6. The power-supply cord of the product should be unplugged from the outlet when left unused for a long 

period  of  time.  When  unplugging  the  power-supply  cord,  do  not  pull  on  the  cord,  but  grasp  it  by  the 
plug.

7.  Care  should  be  taken  so  that  object  do  not  fall  and  liquid  are  not  spilled  into  the  enclosure  through 

openings.

8. The product should be serviced by qualified service personnel when:
     A. The power-supply cord or the plug has been damaged; or
     B. Objects have fallen, or liquid has been spilled into the product; or
     C. The product has been exposed to rain; or

     D. The product does not appear to operate normally or exhibits a marked change in performance; or

     E. The product has been dropped or the enclosure damaged.
9. Do not attempt to service the product beyond that described in the user-maintenance instructions. All 

other servicing should be referred to qualified service personnel.

WARNING

  -

  Do  not  place  objects  on  the  product's  power  cord  or  place  it  in  a  position  where  anyone 

could trip over, walk on or roll anything over it. Do not allow the product to rest on or to be installed over 
power  cords  of  any  type.  Improper  installations  of  this  type  create  the  possibility  of  fire  hazard  and/  or 
personal injury.

SAVE THESE INSTRUCTIONS

WARNING

Page 3

User's Manual

User's Manual

Fig  2.7

Fig  2.8

9.  Choose  copy  menu  to  copy  data  from  the  edited  one  to  other  input/output  channel 

10.  Modify  Device 
       choose  interface  menu  to  set  up  the  start  up  information  of  the  device 

DSC36

DSC36

Содержание DSC36

Страница 1: ...rm or by any means electronic or mechanical including photocopying and recording of any kind DSC36 Loudspeaker Control System USER S MANUAL BACK NEXT ENTER ESC MENU BYPASS PARAMETER USB DEFAULT 1 DEFAULT 2 DEFAULT 3 DSC36 LIMIT 0dBu 48dBu MUTE LIMIT 0dBu 48dBu MUTE LIMIT 0dBu 48dBu MUTE LIMIT 0dBu 48dBu MUTE LIMIT 0dBu 48dBu MUTE OUTPUT INPUT ...

Страница 2: ...e Name of Dealer Full Address DATE OF PURCHASE Nature of the problem Be sure to describe the conditions that existed when the problem occurred and what attempts were made to correct it Other equipment in your system If warranty has expired payment method Cash Check Visa Master card number Signature Enclose this form with the defective unit Do not mail separately ...

Страница 3: ...ential damage resulting from breach of any written or implied warranty R HAUDIO Inc WARRANTYPROVISIONS R H AUDIO Inc will remedy any defect regardless of the reason for failure except as excluded by repair or replacement R H AUDIO Inc will remedy the defect and ship the product within a reasonable time after receipt of the defective product at an R HAUDIO IncAuthorized Service Center TO OBTAIN WAR...

Страница 4: ...directly above or below this unit Because this amplifier has a high power density it has a strongmagneticfieldwhichcaninducehumintounshieldeddevicesthatarelocatednearby This field is strongest just above and below the unit If an equipment rack is used we recommend locating the amplifier s at the bottom of the rack and the preamplifier or other sensitiveequipmentatthetop The lightning bolt triangle...

Страница 5: ...r supply cord do not pull on the cord but grasp it by the plug 7 Care should be taken so that object do not fall and liquid are not spilled into the enclosure through openings 8 The product should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged or B Objects have fallen or liquid has been spilled into the product or C The product has been exposed...

Страница 6: ...SC exits menus back to the default screen 8 Rotary Encoders Three encoders adjust the relevant parameters as displayed on the screen 9 INPUT EDIT buttons illuminate red when pressed and go into mute mode if press for I second it go in to every input channel EDIT mode 10 OUTPUT EDIT buttons illuminate red when pressed and go into mute mode if press for I second it go in to every output channel EDIT...

Страница 7: ... Program and then press ENTER 2 Note that when in a menu ENTER is always used to confirm selections 3 Use the EDIT keys on each output channel with the BACK and NEXT keys to select the high pass filters low pass filters parametrics etc Note that when designing a new crossover the high and low pass filters will be set to default values 4 Use the EDIT keys on each input channel with the BACK and NEX...

Страница 8: ...ns Figure 1 2 Input Delay The maximum available delay of each input is 999 00mS Page 6 Page 11 User s Manual User s Manual Figure 2 3 Setup the Input EQ parameter 4 Setup input channel delay parameter Fig 2 2 Fig 2 3 Gain MS Input A Gain 3 Input Polarity The polarity or phase of each output may be switched individually as below Figure 3 or DSC36 DSC36 ...

Страница 9: ...use Search ID to find the connect devices also you can give the unit ID by hand It can save your time Fig 2 1 2 The Data currently use the unit will upload to Pc when they connected the screen of unit will shows computer connecting SOFTWARE GUIDE Gain or 4 Input Parametric EQ There are six bands of parameter equalisation available on every input The behaviour of each individual band can be changed...

Страница 10: ...hreshold with a release time that is selectable to be a multiplier of the attack time For example as shown below the attack time is 0 3mS and release is 2X so 0 6mS Figure 11 Release Attack Threshold 7 Output Delay The maximum delay of each output is 999 00mS Figure 7 MS 10 Output Parametric EQ There are six bands of parametric equalization available on every output4 The behaviour of each individu...