OR
DIP SWITCH N°1 IN POS. ON
The alarm condition occurs, only if one of the 2 sensors gives
an intruder signal.
Recommended for installation in areas that does not present
environmental disturbance and that requires an elevated capa-
bility of detection.
EI
DIP SWITCH N°2 IN POS. ON
IN THIS POSITION THE DIP SWITCH N°1 DOES NOT HAVE
EFFECT
The alarm condition occurs, if both the sensors, at (or about)
the same time give an intruder signal, (like “AND”) or if there
are many detections of uW with no detection of IRP.
Recommended for installation in areas that require the “AND”
mode but could present shadow zones for the IRP, or for rooms
where sabotage is possible with for example varnish spray on
the IRP lens.
SENS -L
DIP SWITCH N°3 IN POS.ON
Sensitivity detection reduced for both the detectors.
IRP: detection will occur when crossing both edges of a zone
uW: speed detection 0.5 sec. With a human movement of
6.6 Mt/sec.
FUNCTION
LED OFF:
DIP SWITCH N°4
The ON position disables the display of detection and alarm.
With the INHIBIT line connected, when the system will be
armed off, the detector will enable the display for 30 sec. from
the first detection.
MICROWAVE OFF
In the LED OFF mode and with the INHIBIT line connected, at
the arming off of the system, the microwave will be switched off
to not radiate unnecessarily the protected area.
RELAYS INHIBITION
With the INHIBIT line connected, at the arming off of the sys-
tem, the alarm relays will be inhibited.
MEMORIES
With the INHIBIT line connected, at the arming off of the sys-
tem, the memory will be activated. It will display the eventual
memory of the cause that has generated the first alarm, by the
lighting of the LED’s. (see Tab.1), which will be reset by the con-
trol panel unit at its insertion.
If no alarm has been memorised, the LED’s will continue to dis-
play the detection.