INSTALLATION MANUAL
FEATURES
- Microwave OFF
- Digital sampling of the signal
- Modes of detection: EI OR - AND
- Detection sensibility selectable
- Memories of alarm type
- Interactive LED OFF
- Antifliker
- Solid state relay
- Microwave stripline with pulse emission
- Fresnell lens 18 zones on 4 planes With look down zone
- Vertical adjust
- Sealed optics
- Wall tamper
- Cover 90 degrees for 15 Mt
- Corner, wall or bracket mounting
- Bracket (optional) antiviolation
with regulation 90°horiz. 30°vert
The
AKAB-M
is a motion detector with 3 modes of detection,
equipped with two high quality sensors:
A) A dual element infrared (IRP)
B) A microwave microstrip (uW).
Both the sensors are supervised by a microcontroller that opti-
mises performance.
The
AKAB-M
offers the advantage of 3 different modes of de-
tection with two levels of sensibility, which enables the choice
of the most useful for the area to be protected.
In addition to the traditional AND / OR the
AKAB-M
offers the
EI modality recommended for installation in area where is pos-
sible sabotage with spray varnish on the IRP lens.Furthermore
the
AKAB-M
offers a multitude of function among which is the
Microwave OFF and memory of alarm type.
SYSTEM INSTALLATION
Select the best possible location in the room for both the IRP
and uW technologies. If possible, aim the unit towards the
room’s interior and away from windows, moving machinery,
heating and cooling sources
WALL MOUNTING
The maximum range is obtained at mounting height of 2,10 Mt.,
Vertical Adjust in A position (fig 8); It’s possible to mount the de-
tector at a height up to 4 Mt (fig 6-7).
Make sure that the sensor has a clear line of sight to all areas
you wish to protect. Remove the front cover, loosen the screw
and remove the circuit board.
Engrave, as need, the keyholes on the back cover (fig 1), knock
out the Wall Tamper keyhole if required (CEI 79-2 II°Liv.) cut out
the wire keyhole.
1