Sign the holes on the wall having care to sign the hole Wall
Tamper at the centre of the keyhole. Make the fixing hole
(6mm) on the wall. Fix the screw Wall tamper at the wall leav-
ing the screw head out of 5/6 mm. Run the cable through the
wire keyhole.
Fix the back cover on the wall with the screws furnished; make
sure that the screws are securely fixed in their keyholes. Apply
the microswitch Wall Tamper in his housing (fig.2), fold up the
lever so that will remain pushed by the screw and than fix the
tamper cover with the furnished screw.  
Mount  the circuit board.           
Connect the microswitch to the Wall Tamper connector (fig 4).
Wire the cable on the terminals.        

BRACKET MOUNTING  (OPTIONAL)          

Fix the grip A (fig.3) on the wall with the screw furnished.         
Make up the bracket inserting the grip B into the grip A. Re-

move the front cover, loosen the screw and remove the circuit
board. Engrave the bracket keyhole and the wire keyhole on
the bottom of the back cover (Fig.1), and with the screw fur-
nished fix the bottom of the back cover on the bracket.
Direct the back cover to the wanted direction then block it by
clamping the screw.  Run the cable through the house.   
Mount the circuit board.            
Wire the cable on the terminals.                   

Apply power to the AKAB. A 60” self test will be performed; dur-
ing this period the leds will flash alternately. At the end proceed
with the calibration.         

TEST (CALIBRATION)           

UW

Set the trimmer at minimum, (range min. 4mt, max 15mt), go to
the border of the protected area and, with leds off, move to-
wards the unit to verify the detection of the uW and set sensi-
tivity; the green led will light up. Whenever the green led will not
light up increase the range of the uW by turning the trimmer
clockwise;   repeat the test until the required condition is ob-
tained.     

N.B. REGULATION OF THE uW: the range must be regulated
to the minimum necessary because the uW can penetrate walls
and detect from outside the protected area.    

NOTE: regulating the uW at a high range does not improve de-
tection in the desired area.

IRP.             

Mount the front cover and, when leds are off move in the area
where IRP must verify intrusion. The lighting of the yellow led
enables verification of no shadow zones in the protected area.  
DETECTION MODE

AND
DIP SWITCH N°1 IN POS. OFF  

The alarm condition occurs, if both the sensor, at (or about) the
same time give an intruder signal.        
Recommended for installation in areas that could create envi-
ronmental disturbance.

2

Содержание akab-m

Страница 1: ...of the most useful for the area to be protected In addition to the traditional AND OR the AKAB M offers the EI modality recommended for installation in area where is pos sible sabotage with spray varnish on the IRP lens Furthermore the AKAB M offers a multitude of function among which is the Microwave OFF and memory of alarm type SYSTEM INSTALLATION Select the best possible location in the room fo...

Страница 2: ... the screw Run the cable through the house Mount the circuit board Wire the cable on the terminals Apply power to the AKAB A 60 self test will be performed dur ing this period the leds will flash alternately At the end proceed with the calibration TEST CALIBRATION UW Set the trimmer at minimum range min 4mt max 15mt go to the border of the protected area and with leds off move to wards the unit to...

Страница 3: ...on 0 5 sec With a human movement of 6 6 Mt sec FUNCTION LED OFF DIP SWITCH N 4 The ON position disables the display of detection and alarm With the INHIBIT line connected when the system will be armed off the detector will enable the display for 30 sec from the first detection MICROWAVE OFF In the LED OFF mode and with the INHIBIT line connected at the arming off of the system the microwave will b...

Страница 4: ...ERIOD 3 sec RFI IMMUNITY 0 1 to 500 Mhz 3 V m SOLID STATE RELAY 100mA 24V COVER TAMPER 100mA 30V WALL TAMPER 300mA 48V OPERATING TEMP 10 C 55 C CERTIFICATED TEMP 5 C 40 C AMBIENT UMIDITY 95 MTBF TEORIC 98 803 ORE DIMENSIONS 108 x 64 x 46 mm PERFORMANCE LEVEL IMQ I Liv With kit Wall tamper IMQ II Liv MADE IN ITALY 4 ...

Отзывы: