Sign the holes on the wall having care to sign the hole Wall
Tamper at the centre of the keyhole. Make the fixing hole
(6mm) on the wall. Fix the screw Wall tamper at the wall leav-
ing the screw head out of 5/6 mm. Run the cable through the
wire keyhole.
Fix the back cover on the wall with the screws furnished; make
sure that the screws are securely fixed in their keyholes. Apply
the microswitch Wall Tamper in his housing (fig.2), fold up the
lever so that will remain pushed by the screw and than fix the
tamper cover with the furnished screw.
Mount the circuit board.
Connect the microswitch to the Wall Tamper connector (fig 4).
Wire the cable on the terminals.
BRACKET MOUNTING (OPTIONAL)
Fix the grip A (fig.3) on the wall with the screw furnished.
Make up the bracket inserting the grip B into the grip A. Re-
move the front cover, loosen the screw and remove the circuit
board. Engrave the bracket keyhole and the wire keyhole on
the bottom of the back cover (Fig.1), and with the screw fur-
nished fix the bottom of the back cover on the bracket.
Direct the back cover to the wanted direction then block it by
clamping the screw. Run the cable through the house.
Mount the circuit board.
Wire the cable on the terminals.
Apply power to the AKAB. A 60” self test will be performed; dur-
ing this period the leds will flash alternately. At the end proceed
with the calibration.
TEST (CALIBRATION)
UW
Set the trimmer at minimum, (range min. 4mt, max 15mt), go to
the border of the protected area and, with leds off, move to-
wards the unit to verify the detection of the uW and set sensi-
tivity; the green led will light up. Whenever the green led will not
light up increase the range of the uW by turning the trimmer
clockwise; repeat the test until the required condition is ob-
tained.
N.B. REGULATION OF THE uW: the range must be regulated
to the minimum necessary because the uW can penetrate walls
and detect from outside the protected area.
NOTE: regulating the uW at a high range does not improve de-
tection in the desired area.
IRP.
Mount the front cover and, when leds are off move in the area
where IRP must verify intrusion. The lighting of the yellow led
enables verification of no shadow zones in the protected area.
DETECTION MODE
AND
DIP SWITCH N°1 IN POS. OFF
The alarm condition occurs, if both the sensor, at (or about) the
same time give an intruder signal.
Recommended for installation in areas that could create envi-
ronmental disturbance.