EGRO 5511
Manual
HYDRAULIC & STEAM
Steam Boiler
- continued
TS STEAM WAND SOLENOID
Located between the grinder chutes. 3 way
solenoid. Waste ties into drain tray. When
opened, steam is allowed to pass through to
steam wand.
INCOMING WATER SUPPLY
TS STEAM WAND SOLENOID
WATER LEVEL PROBE
INCOMING WATER SUPPLY
Incoming water supply from fill solenoid on the
cold water block.
WATER LEVEL PROBE
Regulates the water level in the steam boiler.
Red wire: Sends data to motherboard.
Blue wire: Grounded on top of boiler,
connects to motherboard.
INJECTION CHAMBER
INJECTION CHAMBER
Union where steam meets water from coffee
boiler, and continues on to hot water tap.