EGRO 5511
Manual
HYDRAULIC & STEAM
Steam Boiler
STEAM BLOCK
Any components that receive steam have
solenoids located on this block.
PRESSURE RELIEF VALVE
STEAM BLOCK
PRESSURE STAT
PRESSURE RELIEF VALVE
Safety valve in case of boiler over-pressurization.
Set at 3 bars of pressure.
PRESSURE STAT
Regulates the pressure of the steam boiler.
Adjustable from the top.
STEAM SOLENOID - HOT WATER
STEAM SOLENOID - HOT WATER
Supplies steam to the mixing chamber for use
with hot water.