background image

PREPARING FOR USE

 

To prevent health problems the RAMSET SG 125E concrete grinder must be  

 

 

connected to an industrial vacuum cleaner (connection diameter 36 mm).

 

Best results are obtained if not too much pressure is exerted on the surface being  

 ground. 

 

For direct grinding against a wall the front end of the dust cap can be removed by  

 

means of a turnbuckle.  This also makes it easier to work on less accessible places.  

 Caution! 

 

Any other grinding work may only take place with a completely fitted protective  

 

cover.

 

The start-up limiter ensures the normal starting of the machine.

 

If permanently overloaded the motor overheats and the machine switches off.  In this  

 

case the machine can only be used again after a cooling timed (3-5 minutes).

 

Changing the cup wheel

 

First and foremost the removable front of the dust cap must be removed.  Then open  

 

the lock and remove the detachable front of the dust cap.  The spanner (1) Ø 32 can  

 

now be used to lock the flange between the machine and the cup wheel.   

 

The spanner (2) can be used to loosen the fixing nut.  Replacement takes place in 

 

reverse order.

 

Changing the brush ring

 

When worn to 5mm the whole brush ring must be changed for a new one.  To do this  

 

one loosens the three fixed brush ring fixing screws and the two screws of the front of 

 

the brush ring to remove the brush.  The new brush ring is pressed in and one    

 

retightens the five screws. (New brushes have a length of 15 mm.)

Отзывы: