background image

TABLE OF CONTENTS

Important Safety Requirements & Instructions …………………………………………….........……. 1
Responsibilities of Installers and Technicians …………………………………………………………. 2
Important Safety Requirements by UL Standards…………………………………….……………….. 3
Classes of Vehicular Gate Operators ...………………………………………………………………... 4
General Specifications ………………………………………………………………………………….... 5
Installation Specifications ………………………………………………………………………………... 6
Hookup Electrical Power - Gate Travel Adjustment …………………………………………………... 7
Standard Installation for Gates from 8' to 16' in Length …………………………………………….... 7
Standard Installation for Gates from 16' to 22' in Length …………………………………………….. 8
Space Required for Standard Gate in the Open Position ………………………………………….... 8
Compact Installation and Minimum Space Required …………………………………………………. 9
Sensor Installation ………………………………………………………………………………………..10
Pushbutton Controls & Master/Slave Installation ……………………………………………………..11
Dip Switch Configuration ……………………………………………………………………………. 12-13
Terminal Strip Connections ………………………………………………………………............... 14-15
Ramset "Intelligate" Control Board ………………………………………………………....…………. 16
Wire Board Connections ………………………………………………………………………………... 17
Exploded View Parts Diagram …………………………………………………………………….…....18
Bill of Materials ………………………………………………………………………………………. 19-20
Troubleshooting Table …………………………………………………………………………….......... 21
Gate Entrance Safety Precautions ……………………………………………………………………. 22
Important Information for The Homeowner………………………………..........……………………. 23
Ramset Optional Accessories …………………………………………………………………………. 24

IMPORTANT SAFETY REQUIREMENTS & INSTRUCTIONS

WARNING To reduce the risk of injury or death:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. Never let children operate or play with gate controls.

Keep the remote control away from children.

3. Always keep people and objects away from the gate.

NO ONE SHOULD CROSS THE PATH OF THE MOVING
GATE.

4. Test the Vehicular Gate Operator monthly.  The gate

MUST reverse on contact with a rigid object or stop
when an object activates the non-contact sensors.
After adjusting the limit of travel, retest the Vehicular
Gate Operator.  Failure to adjust and retest the 

Vehicular Gate Operator properly can increase the
risk of injury or death.

5. Use the Emergency Release only when power switch

or circuit breaker has been turned off. Using the Emer-
gency Release during a power failure can be a
hazard if power is abruptly restored.

6. KEEP GATES PROPERLY MAINTAINED.  Read the

Owner’s Manual.  Have a qualified service person
make repairs to gate hardware.

7. The entrance is for vehicles only.  Pedestrians must

use separate entrance.

8. SAVE THESE INSTRUCTIONS.

WARNING:

Do not install this gate operator if you do not have experience or appropriate
training with gate operators.

1

www.ramsetinc.com

RAMSET

R

AM 3

000 U

L

 - 3100 U

L

 - 3200 U

L

R_Ramset_Ram3000.qxd  8/19/05  4:56 PM  Page 3

Содержание RAM 3000 UL

Страница 1: ...FOR CLASS I II III IV VEHICULAR GATE OPERATORS R_Ramset_Ram3000 qxd 8 19 05 4 56 PM Page 1...

Страница 2: ...www ramsetinc com R_Ramset_Ram3000 qxd 8 19 05 4 56 PM Page 2...

Страница 3: ...death 1 READ AND FOLLOW ALL INSTRUCTIONS 2 Never let children operate or play with gate controls Keep the remote control away from children 3 Always keep people and objects away from the gate NO ONE S...

Страница 4: ...Y DEVICE SUCH AS A PHOTOELECTRIC EYE OR LOOP DETECTOR CHECK THE E R D SENSITIVITY MAKE SURE THAT ALL AREAS AROUND THE GATE ARE SAFE AND SECURE SUCH AS THE FRONT REAR AND TRAVEL AREA COMMUNICATE WITH T...

Страница 5: ...ature to prevent unauthorized use f All warning signs and placards must be installed where visible in the area of the gate g For Vehicular Gate Operators utilizing a non contact sensor in accordance w...

Страница 6: ...s III A vehicular gate operator or system intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public Re...

Страница 7: ...tion 1 4 H R Metal 1 4 H R Metal 1 4 H R Metal Continuous Duty 1 2 Hp 120 Vots AC 3 4 Hp 120 Vots AC 1 Hp 220 Vots AC Motor 4 5 amp 1625 rpm 8 5 amp 1625 rpm 4 5 amp 1625 rpm Power Failure By hand lev...

Страница 8: ...be adjusted depending on local soil conditions 1 Construct form for mounting pad according to dimensions shown in Figure 1 and 2 2 Locate mounting pad according to dimensions given in illustration 3...

Страница 9: ...LENGTH Figure 5 Figure 3 Note 15 amp wires connected to independent breaker HOOKUP ELECTRICAL POWER Figure 4 Gate travel is adjusted by loosening the limit Cams and adjusting them until proper gate tr...

Страница 10: ...com RAMSET RAM 3000 UL 3100 UL 3200 UL SPACE REQUIRED FOR A STANDARD GATE IN THE OPEN POSITION Figure 7 STANDARD INSTALLATION FOR GATES FROM 16 TO 22 IN LENGTH Figure 6 R_Ramset_Ram3000 qxd 8 19 05 4...

Страница 11: ...9 www ramsetinc com RAMSET RAM 3000 UL 3100 UL 3200 UL MINIMUM SPACE REQUIRED FOR COMPACT INSTALLATION Figure 8 Figure 9 20 minimum space required between open gate and wall for this compact installa...

Страница 12: ...Loops on the ground floor prevents gate from closing when vehicle is in loop area Exit Loops on the ground floor opens gate when vehicle crosses loop area Photoelectric Safety Sensor Photo Eye preven...

Страница 13: ...gate Control Board Three pushbuttons are located under the dip switches for operation of the gate see Figure 11 The opening stop and closing buttons can be utilized to set limit switches and verify pr...

Страница 14: ...N Relay maintains a closed contact Dip Switch B 3 CONSTANT WARN Constant warning when gate is in motion Sw Function OFF No effect ON Triggers the prewarn relay to maintain a closed contact while gate...

Страница 15: ...Function OFF Master mode single gate operation All peripheral devices are to be connected to the master operator ON Slave mode used to synchronize operation between two gates Commands are received fro...

Страница 16: ...14 www ramsetinc com RAMSET RAM 3000 UL 3100 UL 3200 UL TERMINAL STRIP CONNECTION Figure 14 R_Ramset_Ram3000 qxd 8 19 05 4 57 PM Page 16...

Страница 17: ...detector is cleared Once the detector is cleared the operator will resume normal operation If triggered twice before reaching a limit switch the alarm will sound for 6 minutes and the control board w...

Страница 18: ...rol Board is powered by a separate mounted 24 VAC transformer This allows no neces sary board modifications between 110 VAC and 220 VAC single phase applications Some of the functions of the Control B...

Страница 19: ...e The open and close are normally open connections and the stop is a nor mally closed connection remove jumper wire when connecting 3 button station Common and stop are also used with a photo eye used...

Страница 20: ...42 27 24 65 71 64 30 39 34 37 41 63 40 45 63 35 63 59 29 58 47 50 49 27 25 31 26 26 27 24 66 33 60 53 33 54 38 57 62 61 1 9 3 6 7 8 5 4 2 43 67 44 57 13 13 38 30 24 52 51 28 27 10 57 18 70 22 48 25 1...

Страница 21: ...lley 1 1 1 19 50 071 2 1 2 Cast Iron Pulley 1 1 1 20 50 076 4L V Belt 170 1 1 1 21 50 085 35 Limit Switch Chain 1 1 1 22 50 086 40 Driver Chain 26 Links 1 1 1 23 50 091 6 x 1 Machine Screw 2 2 2 24 50...

Страница 22: ...3 16 x 3 4 Key Way 4 4 4 58 50 275 1 1 2 UHMW Spacer 1 1 1 59 50 295 8 Self Tap Sheet Metal Screw 2 2 2 60 50 299 Radio Receiver Terminal 1 1 1 61 50 304 120 240 Intelligate Transformer 1 1 1 62 50 31...

Страница 23: ...1 Signal blocked 2 Area not suitable for type of Receiver SOLUTION 1 Reset circuit breaker 2 Replace 1 2 amp fuse 3 Return Control Board for repair 1 A for 1 2 hp motors turn dip switch A 4 On B for 3...

Страница 24: ...estrians should use a separate entrance 3 Always keep people children and objects away from the gate while the gate is in operation No one should cross the area of a moving gate 4 All opening devices...

Страница 25: ...eration No one should cross the area of a moving gate Use the emergency release only when the gate is not moving Make sure when using the foot release or hand crank the circuit breaker for the operato...

Страница 26: ...ry System Key Switch Box Ramset Radio Receiver Ramset Remote Control Transmitter ILD 24 Ramset Plug in Loop Detectors Uphill Hinges Uphill Arms To be used under uneven conditions 20 05 50 40 Mounting...

Страница 27: ...www ramsetinc com R_Ramset_Ram3000 qxd 8 19 05 4 58 PM Page 27...

Страница 28: ...R_Ramset_Ram3000 qxd 8 19 05 4 58 PM Page 28...