PISTON OVERDRIVE

Piston overdrive is a problem that occurs after 
the tool is fired. The piston may extend into the 
work surface as much as 1/2". 

Piston overdrive 

can occur because of several reasons:

• Powder load too strong

• Soft base material

•  Void in the masonry  

material that you're  
fastening into.

• Incorrect fastener selection.

TO AVOID PISTON OVERDRIVE

•  Decrease power level. 

Note: 

Always make test fastenings 
with lightest load and increase 
until proper level is found.

•  Make sure base material is 

checked according to the 
Center Punch Test.

•  When fastening into masonry, 

always make fastenings into 
horizontal joints.

•  Check page 12, "How to Select 

a Power Actuated Fastener."

Caution:

 Constant overdrive will damage the tool beyond repair. For technical  

assistance or service information call 1-877-ITW-BRANDS (1-877-489-2726).

Note: When overdrive occurs, the piston may jam 
into  the  front barrel.  In this  case  be  sure  the  tool 
is  unloaded,  turn  the  tool  upside  down  and  place 
on  the  work  surface.  Strike  the  exposed  piston 
with  a  hammer  until  it  moves  downward  into  the 
barrel. Reset the piston. Wear safety goggles when 
performing this task.

When  fastening  into  concrete  always  maintain  a  minimum  3"  spacing  between  
fastenings and 3" from any free edge. Penetration into concrete should always be 1" 
(see page 12, "How to Select a Powder Actuated Fastener"). The concrete thickness 
should be at least 3 times the penetration depth.

When fastening into steel always maintain a minimum 1-1/2" spacing between fasten-
ings and 1/2" from any free edge. Fastener length should be long enough to penetrate 
the steel completely (see page 12) Steel thickness is limited to 3/16" to 5/16".

Fastening to Concrete

Fastening to Steel

Содержание HD22

Страница 1: ...mset HD22 is a light duty tool designed for applications such as small room additions and basement remodels Tool life will vary depending on work site conditions and application The model HD22 is a lo...

Страница 2: ...SOLE REMEDY AVAILABLE TO THE BUYER NOTE It is very important that the operator of this tool completely reads and under stands the entire tool manual and completes the Operator s Exam on the last page...

Страница 3: ...or piston can seriously injure your hand in the event of an accidental discharge 2 Always use only Ramset fasteners and loads at all times for consistent tool functioning 3 Operators and bystanders mu...

Страница 4: ...erly test fire to determine correct power level may result in overpowering the fastener causing it to pass completely through the work material injuring someone on the other side Overpowering the fast...

Страница 5: ...tool 4 Always hold the tool perpendicular to the work surface to avoid serious injury or death from ricocheting fasteners Use a spall guard whenever possible 5 Never set a fastener too close to anoth...

Страница 6: ...materials 9 Never fasten through or into a hole Always maintain at least 1 2 distance from any pre drilled or pre punched hole 10 Should you decide not to make a fastening after the tool has been load...

Страница 7: ...s could result in serious injury or death 1 A powder actuated fastener after it has been installed is considered a permanent fastening Do not attempt to pull a fastener out of concrete or steel Attemp...

Страница 8: ...th Diameter 1 145 1 1 4 145 1 1 2 145 2 145 2 1 2 145 2 Never unload or disassemble a jammed stuck or broken tool which contains a live powder load This may cause the tool to fire unintentionally Alwa...

Страница 9: ...This action resets the piston for the next fastening Loss of power may be the result of an improperly reset piston 2 Place a fastener point out into the front end of the barrel until the plastic flut...

Страница 10: ...with a sharp firm blow If the tool fails to fire follow the misfire procedure on page 5 Note It is important to strike the firing pin button firmly and squarely A light blow or one off center may not...

Страница 11: ...e three causes for most all misfires INCONSISTENT FASTENER SETTING The major reason for inconsistent fastening is the improper position of the piston There are two reasons for an improperly positioned...

Страница 12: ...r For technical assistance or service information call 1 877 ITW BRANDS 1 877 489 2726 Note When overdrive occurs the piston may jam into the front barrel In this case be sure the tool is unloaded tur...

Страница 13: ...er minimizing uplift Fastener should penetrate steel completely for maximum holding power When fastening into masonry shoot into horizontal joints only Wood to Concrete Wood to Steel Thin Gauge Metal...

Страница 14: ...To Concrete 1B To Steel of Minimum Thickness Required Shank Length of Material Penetration M P Minimum Thickness Thickness Shank Length of Material of Steel 1 4 min pt M S allowance Minimum Thickness...

Страница 15: ...stener is blunted do not fasten the material is too hard True False B If the fastener penetrates easily do not fasten the material is too soft True False C If the material cracks or shatters do not fa...

Страница 16: ...____________________________________________________ Address _________________________________________________________ City_______________________ State________________ Zip _____________ Phone________...

Отзывы: