Configuration page : user and password.
Required to access the configuration pages of the
device.
Do not forget to save your settings.
Authentication.
AES setting
To reset the password and the user, follow these steps:
When starting the device, press the AES1 button (approx. 4 seconds) until the
AES2 indicator lights green.
PHONES
AES 3
AES 1
AES 2
FACTORY
IP
-3
-6
-9
-12
-18
-24
-30
-40
O
dBFs
R
L
Mains
On
OPTION
POWER
V
idéo
MONITORING
SDI silence detector
Button to save configuration changes.
Adjustable from -60 to 0dBFS in 1dB increments
Adjustable from -12 to 0dBFS in 1dB increments
Adjustable from 1 to 120s in 1s increments
Adjustable from 1 to 120s in 1s increments
Parameter
Check box
Value
Comment
Blank Threshold
Enable/disable
0 ~ -60
1. Blank Threshold Filter.
The threshold "Blank threshold" defines the level below which the audio signal is considered as a silence. It is adjustable
from -60dBFs to 0dBFs in steps of 1dB. Enable, this filter generates an alarm of type Audio if there is no signal.
This filter uses the RMS level and not the PEAK level of the signal.
WEB INTERFACE - next -
steps of 1dB
Threshold in dBFs