Only use wood as fuel as described in the firewood section of this manual.
Position 1:
Start up: Air damper is fully open. This position is
only used during kindling and refueling.
Position 2:
Full Primary air: The handle is adjust to the click
position in the middle. This position provides full
primary air intake. During ordinary operation the
handle is to be adjusted to the interval between
pos. 2 and 3. When the flames are clear and yellow,
the damper has been adjusted correctly resulting
in slow/optimal combustion.
Position 3:
Fully closed: The handle is adjust all the way to the
left. This position is used during the ember fase
when the flames are no longer visible. This position
still provides sufficient air for the remaining com-
bustion fase.
WARNING!
Remember the stove is hot while in operation, so keep children, clothing, and
furniture away. Contact with a stove when burning may cause skin burns.
WARNING!
Do NOT fire the stove with the door open!
USING THE STOVE
USING THE STOVE
Adjusting the air control