RAIS/attika Q-TEE Скачать руководство пользователя страница 4

3 - GB

GB

INSTALLATION MANUAL

Congratulations on the acquisition of your new 

RAIS or ATTIKA product! This installation manual 

will ensure that your wood-burning stove is 

installed correctly and that it will provide you with 

comfort and pleasure for many years to come. 

IN GENERAL

It is important that the wood-burning stove 

is correctly installed, in consideration of the 

environment and people’s safety.

Its installation must comply with all local 

rules and regulations, including those that 

refer to national and European standards. 

A certified chimney sweeper should be 

contacted before the installation is started.

No unauthorised alterations may be made to the 

wood-burning stove.

INSTALLATION REQUIREMENTS

Before the wood-burning stove may be taken into 

use the installation must be reported to your local 

chimney sweeper.

There must be the correct supply of fresh air in 

the installation room to ensure good combustion 

– if required, through an AirSystem connection. 

NB: Any mechanical air extraction, for example a 

cooker hood, can minimise the supply of air. 

The wood-burning stove has an air consumption 

of at least 18 m3/h.

The space underneath the combustion chamber is 

not suitable for the storage of flammable material 

unless a reflective insulation panel is fitted!

The floor structure must be able to support the 

weight of the wood-burning stove and a chimney, 

if required. If the existing floor structure does not 

meet this requirement, suitable measures must 

be  taken (e.g. installation of a load distribution 

plate). Seek advice from a building expert.

If the wood-burning stove is to be installed on a 

flammable floor, national

 and local regulations 

must be complied with, including the size of the 

non-flammable plate that must cover the floor in 

front of the wood-burning stove to protect the 

floor from fallen embers. 

The wood-burning stove must be positioned at 

a safe distance from flammable material. Due to 

the risk of fire, flammable items (e.g. furniture) 

may not be positioned closer to the front of the 

glass than the closest permitted distance stated 

in the installation section. When deciding where 

you shall install your RAIS/ATTIKA wood-burning 

stove, you should think about being able to heat 

other rooms in the home, so you get the most out 

of your new stove.

When your wood-burning stove is delivered, 

please check it for defects.

CHIMNEY

The chimney must be high enough to ensure 

that the chimney draught conditions are correct, 

i.e. –14 to –18 pascal. If the recommended 

chimney draught cannot be achieved, problems 

from smoke escaping from the door may arise 

when lighting the fire. We recommend that the 

chimney is adapted to suit the flue outlet spigot. 

The flue outlet spigot is 150 mm in diameter. 

If required a Ø125mm chimney can be used.

If the draught is excessive, it is recommended that 

you equip the chimney with a regulating damper. 

If a regulating damper is fitted, you must ensure 

that there is a free flow area of at least 20 cm² at 

the closed regulating damper. 

Remember that there must be free access to the 

access door on the chimney. 

CO ALARM

An CO alarm must be fitted in the same room as 

the appliance!

INSTALLATION MANUAL

GB

Содержание Q-TEE

Страница 1: ...EDNING BEDIENUNGSANLEITUNG USER MANUAL MANUEL D UTILISATEUR BRUGERVEJLEDNING BEDIENUNGSANLEITUNG USER MANUAL MANUEL D UTILISATEUR BRUKERVEILEDNING BRUKSANVISNING K YTT OHJE GEBRUIKERHANDLEIDING Q TEE...

Страница 2: ...GB...

Страница 3: ...mbustion chamber lining 29 External air connection AirSystem 30 Lubricating the hinges 36 Attaching the legs 37 Q Tee 57 Wall mounted 39 Q Tee C 57 Wall mounted 41 Accessories Q Tee 57 43 Accessories...

Страница 4: ...g installation of a load distribution plate Seek advice from a building expert If the wood burning stove is to be installed on a flammable floor national and local regulations must be complied with i...

Страница 5: ...2 6 2 6 Heating area m2 30 90 30 90 Combustion chamber W x D x H mm 317 X 270 X 270 317 X 270 X 270 Min Uptake pascal 12 12 Weight kg min depending on the model 80 80 Efficiency 80 80 CO emission att...

Страница 6: ...A A A A 8316550 Q Tee 57 Classic R 5 5 565 402 266 114 5 204 435 n 158 388 105 451 n 1 3 0 n 1 6 4 131 5 GB GB GB DIMENSIONAL SKETCHES...

Страница 7: ...A A A A 8316551 Q Tee 57 330 5 266 565 435 388 n 130 n 164 105 451 n 1 5 8 204 114 5 R 5 5 131 GB 6 GB GB DIMENSIONAL SKETCHES...

Страница 8: ...A A 0 1 A A 8316556 Q Tee 57 Classic With legs 114 5 435 665 n158 266 402 388 n 1 6 4 n 1 3 0 205 551 204 n 1 1 0 131 7 GB GB GB DIMENSIONAL SKETCHES...

Страница 9: ...A A 0 1 A A 8316557 Q Tee 57 Glass With legs R 5 5 114 5 665 205 551 435 330 5 266 n 1 5 8 388 204 n130 n164 131 GB 8 GB GB DIMENSIONAL SKETCHES...

Страница 10: ...A A A A 131 n 158 402 266 650 435 388 8316552 Q Tee 65 Classic 114 5 201 190 536 n 1 6 4 n 1 3 0 n 1 4 0 9 GB GB GB DIMENSIONAL SKETCHES...

Страница 11: ...A A A A 650 8316553 Q Tee 65 114 5 201 190 536 n 1 5 8 131 n 164 n 1 3 0 435 388 330 5 266 n 1 4 0 GB 10 GB GB DIMENSIONAL SKETCHES...

Страница 12: ...A A A A 114 5 201 402 266 435 388 n 1 4 0 850 110 390 736 114 5 425 8316554 Q Tee 85 Classic n 1 6 4 n 1 3 0 n 1 2 5 n158 131 11 GB GB GB DIMENSIONAL SKETCHES...

Страница 13: ...A A A A 114 5 201 n 1 4 0 850 110 390 736 114 5 425 8316555 Q Tee 85 n 1 2 5 330 5 266 n130 n164 388 435 n 1 5 8 131 GB 12 GB GB DIMENSIONAL SKETCHES...

Страница 14: ...A A A A 451 105 n 1 2 5 1 7 0 8326550 Q Tee C 57 Classic 330 5 305 565 n 1 5 8 459 528 171 252 166 13 GB GB GB DIMENSIONAL SKETCHES...

Страница 15: ...A A A A 451 105 n 1 2 5 1 7 0 8326551 Q Tee C 57 565 n 1 5 8 459 528 171 252 166 330 5 305 GB 14 GB GB DIMENSIONAL SKETCHES...

Страница 16: ...A A A A 250 208 n 1 1 0 163 665 330 5 305 528 459 n 1 5 8 171 551 205 8326554 Q Tee C 57 Classic With legs 1 7 0 n 1 2 5 15 GB GB GB DIMENSIONAL SKETCHES...

Страница 17: ...A A A A 8326554 Q Tee C 57 Glass With legs 528 459 171 n 1 5 8 665 330 5 305 205 551 n125 170 n 1 1 0 250 163 208 GB 16 GB GB DIMENSIONAL SKETCHES...

Страница 18: ...A A A A 731 385 n 1 2 5 1 7 0 8326550 Q Tee C 85 Classic 330 5 305 845 n 1 5 8 459 528 171 252 264 n 1 1 0 108 n 1 2 5 17 GB GB GB DIMENSIONAL SKETCHES...

Страница 19: ...A A A A 731 385 n 1 2 5 1 7 0 8326550 Q Tee C 85 Glass 845 n 1 5 8 459 528 171 252 264 n 1 1 0 108 n 1 2 5 330 5 305 GB 18 GB GB DIMENSIONAL SKETCHES...

Страница 20: ...ttent operation F Veuillez lire et observer les instructions du mode d emploi Foyer dur e de combustion limit e homologu pour chemin e connexions multiples Utiliser seulement les combustibles recomman...

Страница 21: ...rning stove has two polystyrene blocks 1 which are there to protect the combustion chamber lining during transport These must be removed before starting a fire in the stove The glass cannot be recycle...

Страница 22: ...ANCES INSTALLATION DISTANCES Q TEE 57 The applicable installation distances are shown below The dimensions specified are in mm Installation distances flammable uninsulated flue Right angle installatio...

Страница 23: ...800 GB 22 GB GB INSTALLATION DISTANCES Installation distances flammable Flammable ceiling...

Страница 24: ...3 150 150 150 150 367 5 281 650 650 395 395 23 GB GB INSTALLATION DISTANCES COMBUSTIBLE WALL COVERED WITH 50MM SKAMOTEC 225 INSTALLATION DISTANCES TO FIRE WALL Q TEE 57 The applicable installation dis...

Страница 25: ...CES INSTALLATION DISTANCES Q TEE C 57 The applicable installation distances are shown below The dimensions specified are in mm Installation distances flammable uninsulated flue Right angle installatio...

Страница 26: ...800 25 GB GB INSTALLATION DISTANCES Installation distances flammable Flammable ceiling...

Страница 27: ...150 150 321 414 650 150 150 395 395 6 5 0 GB 26 GB INSTALLATION DISTANCES COMBUSTIBLE WALL COVERED WITH 50MM SKAMOTEC 225 INSTALLATION DISTANCES TO FIRE WALL Q TEE C 57 The applicable installation dis...

Страница 28: ...1 27 GB GB GB HEIGHT ADJUSTMENT The stove is equipped with four adjustment screws 1 under the stove Use the adjustment screws to ensure the stove stands level HEIGHT ADJUSTMENT...

Страница 29: ...burning stove comes with a temporary handle 1 To remove it loosen the screws 2 The new handle 3 can now be attached to the stove FITTING CHANGING THE HANDLE Q TEE C 57 The wood burning stove comes wi...

Страница 30: ...nt combustion chamber lining 2 and remove 3 Lift up the bottom combustion chamber lining 3 4 Remove the side combustion chamber lining sections 4 by turning them inwards at the front until they are lo...

Страница 31: ...installing it in either the floor or the wall behind the stove AIR CONNECTION THROUGH THE FLOOR Q TEE 57 1 Remove the reflector plate 1 by removing the 4 screws 2 2 Tap out the knockout blank in the r...

Страница 32: ...2 2 Tap out the knockout blank in the reflector plate using a hammer 3 Remove the two screws in the damper and one in the bottom of the combustion chamber 3 4 Replace the three screws with spacers 4...

Страница 33: ...ombustion chamber 3 3 Replace the three screws with spacers 4 and use these screws 3 to mount the air box 5 on these spacers 4 Reattach the reflector plate 1 5 Tap out the knockout blank on the rear o...

Страница 34: ...THROUGH WALL 1 Attach the airvalve 3 to the wall with the gasket 2 between the wall and air valve 2 Attach the flexible tube 4 to the connector on the back of the combustion chamber and air valve 3 a...

Страница 35: ...combustion chamber 3 3 Replace the three screws with spacers 4 and use these screws 3 to mount the air box 5 on these spacers 4 Reattach the reflector plate 1 5 Tap out the knockout blank on the rear...

Страница 36: ...THROUGH WALL 1 Attach the airvalve 3 to the wall with the gasket 2 between the wall and air valve 2 Attach the flexible tube 4 to the connector on the back of the combustion chamber and air valve 3 a...

Страница 37: ...B 0 5 A B 0 5 B 0 5 B GB 36 GB GB LUBRICATING THE HINGES LUBRICATING THE HINGES Q TEE 57 Q TEE C 57 The stove must be lubricated regularly at the three moving parts on the closing mechanism and hinge...

Страница 38: ...ate 1 by removing the 4 screws 2 Remove the 4 adjustable feet 3 2 Attach one leg 4 using the screws 2 Do not tighten the screws all the way in order to leave room for the reflector plate 1 3 Attach th...

Страница 39: ...1 1 2 3 GB 38 GB GB ATTACHING THE LEGS ATTACHING LEGS TO Q TEE C 57 1 Remove the 4 adjustable feet 1 2 Attach the legs 2 using the 4 screws 3 4 Now attach the 4 adjustable feet 1 to the legs...

Страница 40: ...Knockout blanks Centre the wall fitting 1 in relation to the wall bushing or at the desired height above the floor Mark out the holes through the holes in the bracket Drill all holes drilling at least...

Страница 41: ...adjust the bracket M4 thread for pointed screws Mount the bottommost wall bracket 4 under the stove using two M6 screws Use the centremost M6 screw 5 to adjust the stove so it is plumb Attach the brac...

Страница 42: ...ied out by authori zed dealers If the oven is to be fitted with a rear outlet the knock out form on the back of the oven must be knocked out The lower wall bracket 3 is mounted under the oven in the t...

Страница 43: ...acket must be horizontal Plastic Rawplugs must not be used Bolts and other fastening material are not included The flue pipe 2 with gasket is mounted on the back of the oven instead of the blind cover...

Страница 44: ...1047 4 Handle Black Leather Glass Door 8311057 1 Handle Black Oak Classic Door 8312033 2 Handle Stainless Steel Classic Door 8312036 3 Handle Brown Leather Classic Door 8312047 4 Handle Black Leather...

Страница 45: ...mm 8320501xx 1 Handle Black Oak 8321033 2 Handle Stainless Steel 8321036 3 Handle Brown Leather 8321047 4 Handle Black Leather 8321057 Ba1 set Automatic door closure 832243090 xx optional colour code...

Страница 46: ...as spare parts from your RAIS ATTIKA dealer See the spare parts list below and spare parts drawing on the next page xx optional colour code POS TOTAL ITEM NO DESCRIPTION 1 1 83120XX Classic glass door...

Страница 47: ...1 2 3 4 5 9 6 7 8 10 GB 46 GB GB SPARE PARTS DRAWING...

Страница 48: ...sed as spare parts from your RAIS ATTIKA dealer See the spare parts list below and spare parts drawing on the next page xx optional colour code POS TOTAL ITEM NO DESCRIPTION 1 1 8311090 Glass door 2 1...

Страница 49: ...2 9 6 7 8 10 1 3 4 5 GB 48 GB GB SPARE PARTS DRAWING...

Страница 50: ...as spare parts from your RAIS ATTIKA dealer See the spare parts list below and spare parts drawing on the next page xx optional colour code POS TOTAL ITEM NO DESCRIPTION 1 1 83211XX Classic glass doo...

Страница 51: ...2 9 6 7 8 10 1 3 4 5 GB 50 GB GB SPARE PARTS DRAWING...

Страница 52: ...ased as spare parts from your RAIS ATTIKA dealer See the spare parts list below and spare parts drawing on the next page xx optional colour code POS TOTAL ITEM NO DESCRIPTION 1 1 8321090 Glass door 2...

Страница 53: ...10 1 7 8 2 3 4 9 6 5 GB 52 GB GB SPARE PARTS DRAWING...

Страница 54: ...igitalt signeret med OCES digitalsignaturen for Kim Sig Andersen Teknologisk Institut This PDF document is only valid if digitally signed with the OCES digital signature for Kim Sig Andersen Danish Te...

Страница 55: ...essment of performance A 4 7 Performance at nominal heat output Level or class of performance including units where relevant Energy efficiency 80 Emission of CO 0 099 Emission of OGC 58 mgC Nm3 Emissi...

Страница 56: ...gt hvis det er digitalt signeret med OCES digitalsignaturen for Kim Sig Andersen Teknologisk Institut This PDF document is only valid if digitally signed with the OCES digital signature for Kim Sig An...

Страница 57: ...GB 56 GB GB...

Страница 58: ...57 GB GB DECLARATION OF PERFORMANCE...

Страница 59: ...GB 58 GB DECLARATION OF PERFORMANCE...

Страница 60: ...BRUKERVEILEDNING BRUKSANVISNING K YTT OHJE GEBRUIKERHANDLEIDING RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais com ATTIKA FEUER AG Brunnmatt 16 CH 6330 Cham Switzerland www attika ch...

Отзывы: