17
Outside temperature, humidity, pressure, wind direction, wind speed, rainfall
(daily total), station voltage, inside temperature. If any optional sensors have
been enabled they will also be displayed.
Sample Read Response (hh:mm value, hh:mm value):
MAX,13:59 24.3,05:07 98,14:07 29.33,05:07 292,05:07 4.0,05:26
0.00,05:07 7.65,07:10 95.4,!AC30
Sample Write Response:
OK
Minimums:
MIN
Description:
Returns the minimum values for each parameter. The time
and value for each parameter are output in comma separated format. The mini-
mum values can be reset by passing the RESET parameter. If any optional sen-
sors have been enabled they will also be displayed.
Values:
?, RESET
Syntax (Read):
MIN=?
Syntax (Write):
MIN=RESET
Output parameters order:
Outside temperature, humidity, pressure, wind direction, wind speed, rainfall
(ignore), station voltage, inside temperature.
Sample Read Response (hh:mm value, hh:mm value):
MIN,05:48 20.5,14:02 70,06:14 29.28,05:08 0,05:07 4.0,05:26
0.00,13:12 7.23,05:20 84.9,!8E11
Sample Write Response:
OK
Real-Time-Clock:
TIME
Description:
If issued without a parameter the device will return the cur-
rent date and time. The clock is set by passing the desired data and time as a
parameter
Values:
YYYY/MM/DD HH:mm:ss
Содержание CC-3000
Страница 12: ...12...