Reset Button 

The reset on the back of the CC-3000 will force a soft reset. This will cause the 
device to reboot but will not reset the system clock. A soft reboot can also be 
initiated by issuing the  “REBOOT” command. Refer to the instruction set for 
details. 

Backup Batteries 

The  CC-3000  must  use  4  AA  NiMH  batteries  for  backup  in  the  event  of  AC 
power  loss.  These 

batteries  are  optional

.  Stored  data  will  not  be  lost  if  the 

batteries  are  not  used.  With  batteries  installed  the  CC-3000  will  continue  to 
function normally with no AC power. The run time will depend on the charge 
state,  capacity  and  age  of  the  batteries.  If  batteries  are  not  installed  the  CC-
3000 will not lose any stored data but it will lose its clock setting and will not 
record any new data while not powered. The clock will reset to the factory de-
fault on power up. 
 
The  CC-3000  will  automatically  detect  when  to  charge  the  batteries  and  will 
keep them fully charged. The CC-3000 charger is a slow charger and will take 
up to 48 hours to recharge a completely depleted battery. 
 
The battery voltage and charger status are available using the command proto-
col but not all 3rd party software programs support this functionality. 
 
It  is  recommended  that  the  NiMH  batteries  are  replaced  every  year  for  opti-
mum performance. 
 

- USE RECHARGEABLE NiMH BATTERIES ONLY!- 

 
 
 
 
 
 

Software/Firmware Updates 

The software or firmware in the CC-3000 can be updated or changed using 
either the USB or RS-232 connection depending on the model. Updates can not 
be performed using the RS-485 port.  Updates will be posted on the Rainwise 
website. Versions will vary depending on model. Make sure you read the up-
date instructions carefully to be sure you are installing the correct software. As 
with all updates there are risks associated with changing the flash memory.  
Updates are loaded using a Windows based program called IAPflash. This pro-
gram is supplied with the “.enc” file along with instructions.  Windows is re-
quired to perform updates. No other operating systems are currently supported. 

Содержание CC-3000

Страница 1: ...Rev 0 May 15 2011 Rainwise CC 3000 CC 3000R User s Guide P O Box 443 Bar Harbor Maine 04609 0443 207 288 5169...

Страница 2: ...reserved No part of this work may be reproduced in any form except by written permission of the publisher All rights of translation are reserved Rainwise CC 3000 is a trademark of Rainwise Inc Rainwi...

Страница 3: ...vers USB Models only 7 Connecting 418 433 MHz Models 8 Connecting LR Models 9 Connecting USB USB Models Only 9 Connecting RS 232 RS 232 485 Models Only 9 Connecting RS 485 422 RS 232 485 Models Only 9...

Страница 4: ...erial bridge Using a virtual com port VCP driver the CC 3000 will appear as a serial communications port on the host system The VCP drivers were written and supplied by FTDI VCP Specifications Port US...

Страница 5: ...is available in several variants Part numbering system CC 3000_ _ _ 41 418 MHz 42 433 MHz _ _ 2 4 GHz LR compatible R Serial RS 232 RS485 _ USB 2 0 Common Specifications Power Requirements 9 VDC to 12...

Страница 6: ...5 422 Mode 2 wire half duplex Connector 3 position screw terminal A B and signal ground Max Speed 115 200 bps Termination 120 ohms internal jumper enable 2 4 GHz Specifications Frequency Spread spectr...

Страница 7: ...00 requires a virtual comport driver Drivers are provided on the CD ROM supplied with the CC 3000 There are two methods for installing the drivers Automatic or Manual Automatic Driver Install 1 Insert...

Страница 8: ...at www rainwise com Connecting 418 433 MHz Models 418 and 433 MHz models have external receivers Connect the components as shown below Ensure that power is applied only after all the receiver connec t...

Страница 9: ...s designed to connect to a DTE device such as a computer The RS 232 port can not be used simultaneously with the RS 485 port Connecting RS 485 422 RS 232 485 Models Only The CC 3000R is supplied with...

Страница 10: ...stations can be coded to prevent interference from another MK III weather station that is located in radio range A dipswitch in the sensor assembly selects a station number from 0 to 3 The default is...

Страница 11: ...ep them fully charged The CC 3000 charger is a slow charger and will take up to 48 hours to recharge a completely depleted battery The battery voltage and charger status are available using the comman...

Страница 12: ...12...

Страница 13: ...esponse OK Get Column Headers HEADER Description Returns a series of comma delimited text descriptions These descriptions are used to identify the type and order of the returned data in both NOW and D...

Страница 14: ...returned if the unit has not received a transmission from the weather station Values None Syntax NOW Sample Response 2011 01 16 12 45 47 22 1 80 29 30 270 2 0 9 0 0 00 7 35 2 46 49 2 6ACA Auto Output...

Страница 15: ...0 is the maximum value Values 0 60 Syntax Read LOGINT Syntax Write LOGINT minutes Sample Read Response 5 Sample Write Response OK Memory Management MEM Description When set with the device returns the...

Страница 16: ...e CC 3000 will record even while outputting This means that should a logging interval occur during the download this record will also be output The output stops on the last available record Values Non...

Страница 17: ...at The mini mum values can be reset by passing the RESET parameter If any optional sen sors have been enabled they will also be displayed Values RESET Syntax Read MIN Syntax Write MIN RESET Output par...

Страница 18: ...120 max Daylight saving can be disabled by setting the daylight saving to zero Values MM DD HH mm MM DD HH mm mm Syntax Read DST Syntax Write DST MM DD hh mm MM DD hh mm mm DST 0 disable daylight savi...

Страница 19: ...the reset command The counter counts in 0 01 in crements and rolls over at 65536 counts Issuing the rainfall reset command will clear all rainfall counters including the current daily rainfall Values...

Страница 20: ...must match the weather station Values 0 3 Syntax Read STATION Syntax Write STATION number Sample Read Response 2 Sample Write Response OK Software Reboot REBOOT Description Forces a soft reboot of the...

Страница 21: ...for the NOW DOWNLOAD MIN and MAX com mands Values ENABLE DISABLE Syntax Read SOLAR Syntax Write SOLAR ENABLE or SOLAR DISABLE Sample Read Response ENABLED Sample Write Response OK UV Index UV Descript...

Страница 22: ...ABLE or T1 DISABLE or T2 ENABLE or T2 DISABLE Sample Read Response ENABLED Sample Write Response OK Calculating the Checksum The CC 3000 uses a 16 CRC checksum The CRC uses the same polynomial as the...

Страница 23: ...t int _data unsigned char n for n 8 n n if acc 0x8000 0 acc 1 _data 1 if _data 256 0 acc acc 0x1021 else acc 1 _data 1 if _data 256 0 acc Return CRC accumulator unsigned short int crc16Acc void unsign...

Страница 24: ...e the fixing of any attachment not provided with the product or damage due to a lightning strike Rainwise will not reimburse for take down or reinstallation charges Rainwise will not pay for any warra...

Отзывы: