6. Sanitize the Conditioner
• Mix a 3/4 cup of common (unscented) 5.25% household bleach
with 1 quart of water. Pour this solution into the brine well.
• Initiate a manual regeneration. The solution will be drawn into the
conditioner during the regeneration process.
• After the system has completed a manual regeneration, the condi-
tioner will be sanitized and ready for use.
14
!
Important Note: Do not pour
undiluted bleach into the water
conditioner.
Correct Stacking Using
- 50 lb Salt Blocks
Standard Block Dims
- 8.5 x 8.5 x 11.5
Total Blocks Possible
- 4 =200 lbs of Salt
Level - 4.0 level
- equal to 200 lbs
(Correct)
Incorrect Stacking Using
- 50 lb Salt Blocks
Standard Block Dims
- 8.5 x 8.5 x 11.5
Total Blocks Possible
- 3 =150 lbs of Salt
Level - 4.0 level
- equal to 200 lbs
(Not Correct)
I N COR R ECT STACKING
COR R ECT STACKING
STACK I N G BLOCK SALT - 50 lbs B LOCK S
11.5"
8.5"
8.5"
STACK I N G BLOCK SALT - 25 lbs B LOCK S
I NCOR R ECT STACKING
COR R ECT STACKING
Incorrect Stacking Using
- 25 lb Salt Blocks
Standard Block Dims
- 8 x 6 x 8.5
Total Blocks Possible
- 6 =150 lbs of Salt
Level - 4.0 level
- equal to 200 lbs
(Not Correct)
Correct Stacking Using
- 25 lb Salt Blocks
Standard Block Dims
- 8 x 6 x 8.5
Total Blocks Possible
- 8 =200 lbs of Salt
Level - 4.0 level
- equal to 200 lbs
(Correct)
6"
8.5"
8"
Содержание EC5 Series
Страница 26: ...26 Valve Exploded View...
Страница 28: ...28 Control Exploded View 1 5 3 4 4 6 11 7 8 8 10 9 14 2 15 12 13...