4.  Flush the Hot Water Heater

       • Run hot water in the bathtub until the water tests soft.

5.  Add Salt to Brine Tank

          Salt Recommendations

          RainSoft Water conditioners use water softener Block Salt, Solar 
          Salt (Pellet), or Potassium Chloride. Your Dealer will provide a 
          recommended type of salt to use. Go to the Main Menu, >
          Configure Settings, >Salt Settings, to change your Salt Type 
          (Sodium or Potassium) and Salt Form (Pellet or Block)

          

Adding Salt to your Brine Tank

       

1

) Fill your Salt Tank with Block Salt, Solar Salt (Pellet) or 

          Potassium Chloride. The RainSoft standard brine tank can hold a
          max of 250 lbs. [113kg] or LEVEL 5.0 of Pellet form Salt and 200 
          lbs. [90kg] or Level 4.0 of Block form Salt.

       • Solar Salt and Potassium Chloride generally come in 40 lbs. Pellet

          Form Bags. Fill tank with pellets by empting contents right into 
          center of brine tank.

       • Block Salt comes in 25 lbs. blocks or 50 lbs. blocks. See Block 

          Stacking Figures on page 14  for correct and incorrect stacking 

       of block salt.

       

2

)  On your EC5, press any button from the home screen to enter 

          the Main Menu, then select >SALT LEVEL, Press Enter or Right 
          Arrow button. Using the Up and Down Arrows, set the Salt Level
          to the level of salt that is filled in the brine tank. You can          
          reference the weight of salt you entered for more precise 
          entering of amount of salt used. Level of 1.0 is equal to 50 lbs. 
          22kg] of  salt.

          3) Press Enter Button to save new salt level and exit salt level 
          screen. Press the Left Arrow button to exit the Main Menu and 
          return to the Home Screen.

          

Note: Exiting Salt Level screen with the Left Arrow button will 

          

NOT

save new salt settings

.

!

Important Note: It is important
to maintain at least 15 lbs. to 30
lbs. of salt in your brine tank to
correctly regenerate your
System and to continue to enjoy
soft water. LOW SALT ALERTS
will activate for salt levels
under 30 lbs.

!

Recommendations: If choosing to
use both Block and Pellet form of
salt when filling your brine tank,
we recommend you maintain your
settings on Pellet Form. We do not
recommend this method of filling
your brine tank for system sizes of
EC5 150 and higher. The total
volume of salt in the full brine
tank will not allow enough room
for water to make the appropriate
amount of brine solution to
regenerate your system fully.

Содержание EC5 Series

Страница 1: ...heet for specific reduction claims Part No 16842 Rev F 08 16 The EC5 series is tested and certified by WQA to NSF ANSI 372 for lead free compliance The EC5 series is tested and certified by WQA to CSA...

Страница 2: ...Product Certification Information 7 Installation Instructions 8_12 System Start Up 12 14 An Overview of the Regeneration Process 15 16 Navigating the menus 17 18 Salt Level 18 System Information Star...

Страница 3: ...t amount of salt for maximum efficiency based on your individual water consumption needs Application Limitations On hardness levels of 60 grains and higher the system may not achieve a hardness of les...

Страница 4: ...unsafe or of unknown quality without adequate disinfection before or after the system This system must be installed in accordance with all applicable state and local laws and regulations The Commonwe...

Страница 5: ...0 0 2 0 11 0 34 500 15 0 lbs 30 500 10 0 lbs 14 200 3 0 lbs 4 750 3 0 lbs EC5 100S V 10 x 35 1 0 10 0 2 0 10 0 34 500 15 0 lbs 30 500 10 0 lbs 14 200 3 0 lbs 4 750 3 0 lbs EC5 100S CV 10 x 35 1 0 10 0...

Страница 6: ...3 500 3 0 lbs 4 516 3 0 lbs EC5 100S T 10 x 35 1 0 10 0 2 0 10 0 30 500 15 0 lbs 26 100 10 0 lbs 13 500 3 0 lbs 4 516 3 0 lbs EC5 100S CT 10 x 35 1 0 10 0 2 0 11 0 30 500 15 0 lbs 26 100 10 0 lbs 13 5...

Страница 7: ...ailable at no charge from RainSoft Please call 1 800 860 7638 for your free two year supply In between testing you can easily monitor the system s performance in the shower or while washing your hands...

Страница 8: ...s over 50 feet long may need to be increased in size to allow proper flow Place the system in the desired location The location should have a level smooth and clean surface If the system is located ou...

Страница 9: ...igation or Outdoor Watering If available run an untreated water line to outside faucet or provide a hose connection on untreated line prior to system 8 Install the Pipe Connector Yoke to the Bypass Va...

Страница 10: ...osition The valve handles should be perpendicular to the pipes see figure 4 9 Install the Drain Line and Air Gap Air Gap Not Supplied For all drain lines use at least a 1 2 inch I D line Connect the d...

Страница 11: ...n the right side of the valve see figure 8 Insert a tube support into the other end of the brine line and push the brine line into the brine safety float elbow Use a locking clip to secure the connect...

Страница 12: ...e Remaining Debris from the System Open the cold water faucet on your bathtub Allow the system to flush the remaining dirt and debris into the bathtub until the water runs clear Open all remaining fau...

Страница 13: ...en to enter the Main Menu then select SALT LEVEL Press Enter or Right Arrow button Using the Up and Down Arrows set the Salt Level to the level of salt that is filled in the brine tank You can referen...

Страница 14: ...l Blocks Possible 4 200 lbs of Salt Level 4 0 level equal to 200 lbs Correct Incorrect Stacking Using 50 lb Salt Blocks Standard Block Dims 8 5 x 8 5 x 11 5 Total Blocks Possible 3 150 lbs of Salt Lev...

Страница 15: ...valve to the brine refill position about two hours before the scheduled time of regeneration You may hear the motor running and some water flowing at this time Because the computer knows how much wate...

Страница 16: ...w position In this position the valve creates a vacuum to pull the brine solution out of the brine tank The brine solution flows slowly through the mineral bed removing the hardness ions that are atta...

Страница 17: ...up to the system There are a few special screens that will be described in the REGENERATION and ALARMS sections of this manual The screen has a backlight that turns off after a few minutes of no activ...

Страница 18: ...ER or RIGHT button takes you to the System Information menu You can select any menu items for additional information System Alerts When salt level falls to 30 pounds or less you will receive a LOW SAL...

Страница 19: ...onitor these system and provide a warning when service is needed These alarms are identified as DRINKING WATER FILTER AIRMASTER and OTHER These alarms indicate the need for service by a trained techni...

Страница 20: ...g SYSTEM REGEN IN 10 The control does a 10 second countdown before starting the regenera tion This gives you one more chance to abort the manual regeneration Pressing any button during the 10 second c...

Страница 21: ...at the same time the next day Salt Type You have the option to use sodium chloride or potas sium chloride salt Sodium chloride is less costly and more readily available Some people may prefer potassiu...

Страница 22: ...f Week Sets the current day of the week Set Date Sets the current date mm dd yyyy in English dd mm yyyy in metric Daylight Savings Turns automatic Daylight Savings Time adjustment ON or OFF The system...

Страница 23: ...ion is informational only and cannot be changed directly Network Status In the Wi Fi Menu scroll down to see Network Status This will change from No SSID to the assigned IP address when connected to t...

Страница 24: ...rn to the RainSoft Remind App Press Connect EC5 to Network at the bottom of the screen 5 Enter your home network Wi Fi SSID and password in the appropriate fields then press Connect to Network As the...

Страница 25: ...ion is complete 2 The system regenerates at the wrong time 1 The raw water has changed 2 The bypass valve is open 3 The power supply is disconnected 3 Plug in the power supply 1 Call your RainSoft Dea...

Страница 26: ...26 Valve Exploded View...

Страница 27: ...7954 Flow control washer 0 25 gpm 21 1 17957 Adapter blfc 0 25 gpm 22 1 17939 1 2 npt x 1 2 barb poly elbow 23 1 17557 Composite bypass valve 24A 1 17560 3 4 coupling adapter assembly 24B 1 17558 Turb...

Страница 28: ...28 Control Exploded View 1 5 3 4 4 6 11 7 8 8 10 9 14 2 15 12 13...

Страница 29: ...ONT HOUSING ASSEMBLY 7 1 51904 GEN5 DOOR EC5 8 5 51919 SCREW 4 20x0 25in PHIL PAB SS 9 1 51927 EC5 WIFI PCB BOARD ASSY PRG 10 1 51911 LED BLUE WIRE HARNESS GEN5 11 1 51907 SPRING GEN 5 FRONT HOUSING D...

Страница 30: ...cm2 OPERATING TEMPERATURE 40 F 100 F 4 4 C 38 C ELECTRICAL 24 VAC 50 60 Hz COMPUTER SALT PER REGENERATION VARIABLE EFFICIENCY 4 400 GRAINS LBS SALT 2 25 LBS DOSAGE CAPACITY SALT 9 900 GRAINS 2 25 LBS...

Страница 31: ...MENT NEEDS THE SYSTEM SHOULD BE INSTALLED IN AN AREA NOT AFFECTED BY EXTREME HEAT COLD OR THE ELEMENTS THIS SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL LAWS AND REGU LAT...

Страница 32: ...f cm2 OPERATING TEMPERATURE 40 F 100 F 4 4 C 38 C ELECTRICAL 24 VAC 50 60 Hz COMPUTER SALT PER REGENERATION VARIABLE EFFICIENCY 4 970 GRAINS LBS SALT 4 5 LBS DOSAGE CAPACITY SALT 22 400 GRAINS 4 5 LBS...

Страница 33: ...ental or consequential damages so parts of the above limita tion or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from stat...

Страница 34: ...RainSoft Division of Aquion Inc 101 S Gary Ave Roselle IL 60172 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2016 RAINSOFT A DIVISION OF AQUION INC 36...

Отзывы: