![RainSoft EC5 Series Скачать руководство пользователя страница 28](http://html2.mh-extra.com/html/rainsoft/ec5-series/ec5-series_installation-and-service-manual_3504719028.webp)
28
8 Steps to Successful Service
The following procedure is a complete system check to help diagnose
problems with the equipment. If the system fails to perform properly
in any of the following steps, please refer to “Troubleshooting Guide
for the 8 Steps to Successful Service” on pages 31-32.
1. Understanding the Nature of the Call
• Understanding the nature of the call can be the difference
between a successful service call and a return visit. With
understanding the customer’s expectations, it is very easy to
test the system, find that it is functioning mechanically correct,
and yet overlook the customer’s real concerns.
2. Test the Cold, Hot, and Raw Water
• Hot/hard; Cold/soft: Problem with capacity or incorrect settings.
Hot/soft; Cold/hard: Problem with capacity or incorrect
settings.
Hot/slightly hard; Cold/slightly hard: Bleed through problem.
Hot/hard; Cold/hard: Major mechanical problem.
• Document the results on the service order.
3. Perform a Visual Inspection and Check the
Programming
• Verify that the bypass valve is in the service position.
• Does the brine tank have salt and the correct amount of water?
Computer units should have about 3 inches of water in the brine
tank, except in a regeneration cycle.
• Verify that the valve is in Service. The piston rod alignment screw
should be aligned with the number 2 on the piston rod.
• Verify that the computer is programmed to the correct values in
terms of the capacity of the system, raw water hardness, and/or
iron increases or decreases.
• Document the diagnostics on the service order.
4. Perform a Mechanical Function Test
• Press any key from the home screen to get to the main menu.
• Select START REGENERATION from the main menu and
pressing either the ENTER or RIGHT button takes you to the
options of initiating a manual regeneration. This menu
offers two options: Start a regeneration now or start it later.
Regen Now ?
Press the Enter button while this item is
highlighted
.
Screen will show confirm
REGEN NOW
.
Press ENTER while“
YES
” is highlighted.
The computer will provide a 10 second countdown before
regeneration.
• The system in now in
Cycle 1
(Brine Refill
)
. The piston
rod cycle indicator is aligned with position number 1, the brine
stem is depressed, and water is flowing to the brine tank.
Helpful Tip: The system may be running out
of capacity, providing a false reading.
!
Important Note: The EC5 will adjust brine
refill time based on incoming pressure.
Please measure and set incoming pressure
on the EC5 control for most accurate brine
refill.