16
SERVICE MENU
>
Configure System
>
System Info
>
System Testing
>
Dealer Info
>
Wi-Fi Settings
Press
UP
ARROW 2x
Enter Authorize Code:
< Drinking Wat er >
Typ e:
None/Ultrefiner/Hydref iner/O the r
Install Date :
00/00/000 0
Ser vice Interval
Off /Time: 6 to 8 4 Mont hs
Ser vice Re ma ining
# Months RES ET:
No / Ye s
< House Filter >
Typ e:
None /Carbon/Neut ralizer/Sedim ent/Ot her
Install Date :
00/00/000 0
Ser vice Interval
Off /Time/Vol: 6 to 8 4 Months 10 K to 99 0K
Gals
Ser vice Re ma ining
# Months / GA LS RESE T:
No / Ye s
< Sys tem 1 >
Typ e:
None /Clean Start/ AirMaster/ UV / Ultra
filte r / Other
Install Date :
00/00/000 0
Ser vice Interval
Off /Time: 6 to 8 4 Mont hs
Ser vice Re ma ining
# Months RES ET:
No / Ye s
< Sys tem 2
Typ e:
None /Clean Start/ AirMaster/ UV / Ultra
filte r / Other
Install Date :
00/00/000 0
Ser vice Interval
Off /Time: 6 to 8 4 Mont hs
Ser vice Re ma ining
# Months RES ET:
No / Ye s
USE LEFT & RIGHT ARROW
BUTTONS
TO NAVIGATE BETWEEN ADDITIONAL
SYSTEMS MENUS
EC5 Home Screen
Additional Systems
Press & Hold
LEFT
ARROW
5 to 7
Seconds – Access
Additional Systems
Screens.
Press & Hold
UP
ARROW
5 to 7
Seconds –
SERVICE MENU.
CLEAR ALARMS &
ALERT MESSAGES
Press & Hold
DOWN
ARROW
5 to 7
Seconds – to clear all
active alarms and
alerts
PROGRESS THRU EACH
REGENERATION STEP,
ONLY DURING REGEN.
Press & Hold
RIGHT
ARROW
5 Seconds –
During Regen to
Progress thru Cycles.
EC5 SERVICE MENU Screen
EC5 FLOW CHART;
EC5 HIDDEN KEYS
Program RS VER - 1.2 – 1.4
FLOW CHART HIDDEN KEYS