RAINSMART RainSmart Скачать руководство пользователя страница 9

 
 

b)

 

Float / Retention Gland / Reserve Level Installation (see Fig. 4)

: Using the 

retention gland

 provided. 

Drill a 19 mm hole near the hatch door or down pipe water strainer at the top of the tank in a position of 
easy access. Fit  the Gland and  feed the cable through the gland  hole from inside the tank. Tighten the 
gland. It will support the weight of the Float Switch. Tie Float Switch and Motorised Ball Valve cables 
to the mains power cable using the cable ties supplied, to provide strain relief on the connectors. 

 

Rainsmart gives you the flexibility of setting a tank water 

reserve level

. A reserve level is a level you 

set  in  the  tank  to  signify  the  point  at  which  the  Float  Switch  is  at  its  lowest  point.  You  can  set  this 
reserve level at any height in the tank. This will ensure that you always have the water you require for 
anything other than the toilet and laundry (i.e. garden). Begin by extending the Float Switch lead outside 
the tank. Hold the lead at the top of the tank and hang until the Float head is 100 mm above the pump 
suction pipe (the pipe which links the tank to the pump). Then, still holding the Float lead at the top of 
the  tank,  raise  the  Float  head  by  pulling  up  the  Float  lead.  When  you  are  content  with  the  Float  head 
height (which may be a quarter or half way up the tank) place a mark on the Float lead at the height of 
the tank with a pen. This mark will be the point at which the Retention Gland holds the Float lead. This 
is also your determined reserve level. You can later adjust the reserve level to suit your requirements by 
releasing the Retention Gland and feeding the Float lead either way.  
 
Note:  Ensure  you  consider  what  reserve  level  you  would  like  in  the  tank  and  that  the  length  of  cable 
inside the tank allows the Float Switch room to fully extend. 
 
Wire the Float Switch (as shown in the Quick Setup) into the socket at the bottom of the 

RainSmart

TM

 

controller. 

RainSmart

TM

  recommends testing  the  Float  Switch  prior to installation. To do this, switch 

power onto the 

RainSmart

TM

 controller and move the Float Switch from a low to a high position. When 

the  Float  Switch  is  held  in  the  low  position  the  control  box  ‘mains  water’  light  will  illuminate. 
Additionally, if the Motorised Ball Valve is plugged in, this will open. When the Float Switch is held in 
the  up  position  the  control  box  ‘rain  water’  light  will  illuminate.  Additionally,  if  the  Motorised  Ball 
Valve is plugged in, this will close. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание RainSmart

Страница 1: ......

Страница 2: ...ION 6 MOUNTING RAINSMARTTM CONTROLLER 7 WIRING FLOAT SWITCH AND MOTORISED BALL VALVE 6 RAINSMARTTM QUICKSETUP 8 INSTALLING DUAL CHECK VALVE 8 INSTALLING FLOAT SWITCH 11 INSTALLING MOTORISED BALL VALVE...

Страница 3: ...ly with applicable local standards The low voltage connections need not be carried out by a qualified electrician but should be done in compliance with applicable standards Do not use long extension l...

Страница 4: ......

Страница 5: ...ies If there is no water in the Tank the Motorised Ball Valve opens allowing Mains water to pass through the Dual Check Valve gold valve beside Motorised Ball Valve as depicted above to the Amenities...

Страница 6: ...duct complies with relevant electrical standards and has Watermark approval number 23029 1 GENERAL INFORMATION The RainSmartTM controller can be used in either above ground or below ground tank instal...

Страница 7: ...3 WIRING FLOAT SWITCH AND MOTORISED BALL VALVE The Float Switch and Motorised Ball Valve are low voltage for your safety...

Страница 8: ...It is necessary to install the Dual Check Valve as described This installation method will adhere to government requirements The installation must be carried out by a licensed plumber 5 INSTALLING FL...

Страница 9: ...Float lead at the top of the tank raise the Float head by pulling up the Float lead When you are content with the Float head height which may be a quarter or half way up the tank place a mark on the...

Страница 10: ...FIG 4...

Страница 11: ...at switch once again in the upright position so that the valve closes Once closed pull the valve plug out from the socket The valve should open You may also use the test button to check the valve oper...

Страница 12: ...s the result of an acceptable water level sensed by the Float Switch The Motorised Ball Valve will be in the closed position Pump Auto Signifies the pump being controlled by the Float Switch The pumps...

Страница 13: ...n Gland 2 x Cable Ties RainSmartTM PUMP BOX 1 x RainSmartTM Controller 1 x Motorised Ball Valve 1 x Float Switch 1 x Dual Check Valve 1 x Plastic Threaded Tee 1 x Plastic Threaded Nipple 1 x Plastic T...

Страница 14: ...FIG 1...

Страница 15: ......

Страница 16: ...General Test B verify rain water level Perform General Test B2 Verify float sensor 2 No water being delivered by pump Perform General Test A verify RainSmartTM power supply Perform General Test E ver...

Страница 17: ...m General Test B2 Verify float sensor Tank empty Mains Water indicator ON Perform General Test D Verify Mains Valve operation TABLE 2 GENERAL TESTS The following general tests must be used in conjunct...

Страница 18: ...al If not return the RainSmartTM unit for service as a failure has occurred D Verify Mains Valve operation Press the test button Mains valve operates There is a visual indicator on top of the mains va...

Страница 19: ...orised workshop labour will be free of charge for the first 12 month period from date of the first consumer purchase when unit is found to have failed due to defective workmanship or material supplied...

Страница 20: ...y and fitness for a particular purpose exclusion of damages Rainsmart Australia Pty Ltd liability is limited to the cost of repair or replacement of the product Rainsmart Australia Pty Ltd shall not b...

Страница 21: ...Please do not return Warranty Retain for your records Purchased From Purchase Date Serial No Model No RAINSMART ASUTRALIA PTY LTD Australia Head Office RainSmart Australia Pty Ltd PO Box 835 Lutwyche...

Страница 22: ......

Отзывы: