 INSTALLATION AND USER GUIDE

 

 
Thank you for choosing the Australian owned, designed and manufactured 

RainSmart

TM

.

 We trust that you will 

enjoy the quality and freedom the 

RainSmart

TM

 has been designed to provide. Please read this instruction guide 

carefully  to  make  sure  the

  RainSmart

TM

    is  installed  correctly  to  ensure  its  many  design  features  are  used  to 

your full advantage. 
 
The 

RainSmart

TM

  can  be  installed  with  many  types  of  pressure  pumps.  A  tank  water  reserve  level  (of  your 

choice) combined with 

RainSmart

TM

’s 

Pump Manual override ensures flexibility. 

 
The product complies with relevant electrical standards and has Watermark approval number: 23029 

 

1.

 

GENERAL INFORMATION 

 

The 

RainSmart

TM

  controller can be used in either above ground or below ground tank installations. A pressure 

pump is required. 
 

2.

 

MOUNTING 

RAINSMART

TM

 CONTROLLER 

 

The controller must be installed on a vertical surface using the supplied mounting brackets. Install the controller 
within 2 meters of a protected power supply and no more than 10 meters from the Tank and Float Switch or the 
Motorised Ball Valve unless extension cables are used.  Connect wall mounting clips to 

RainSmart

TM

 Control 

Box using smaller screws provided (

SEE FIG. 

2). Then mount 

RainSmart

TM

 Control Box on wall using larger 

screws and nylon anchors (depending on type of surface fixing to). 

 

     

FIG. 2

 

 
 
 
 
 
 
 
 

Содержание RainSmart

Страница 1: ......

Страница 2: ...ION 6 MOUNTING RAINSMARTTM CONTROLLER 7 WIRING FLOAT SWITCH AND MOTORISED BALL VALVE 6 RAINSMARTTM QUICKSETUP 8 INSTALLING DUAL CHECK VALVE 8 INSTALLING FLOAT SWITCH 11 INSTALLING MOTORISED BALL VALVE...

Страница 3: ...ly with applicable local standards The low voltage connections need not be carried out by a qualified electrician but should be done in compliance with applicable standards Do not use long extension l...

Страница 4: ......

Страница 5: ...ies If there is no water in the Tank the Motorised Ball Valve opens allowing Mains water to pass through the Dual Check Valve gold valve beside Motorised Ball Valve as depicted above to the Amenities...

Страница 6: ...duct complies with relevant electrical standards and has Watermark approval number 23029 1 GENERAL INFORMATION The RainSmartTM controller can be used in either above ground or below ground tank instal...

Страница 7: ...3 WIRING FLOAT SWITCH AND MOTORISED BALL VALVE The Float Switch and Motorised Ball Valve are low voltage for your safety...

Страница 8: ...It is necessary to install the Dual Check Valve as described This installation method will adhere to government requirements The installation must be carried out by a licensed plumber 5 INSTALLING FL...

Страница 9: ...Float lead at the top of the tank raise the Float head by pulling up the Float lead When you are content with the Float head height which may be a quarter or half way up the tank place a mark on the...

Страница 10: ...FIG 4...

Страница 11: ...at switch once again in the upright position so that the valve closes Once closed pull the valve plug out from the socket The valve should open You may also use the test button to check the valve oper...

Страница 12: ...s the result of an acceptable water level sensed by the Float Switch The Motorised Ball Valve will be in the closed position Pump Auto Signifies the pump being controlled by the Float Switch The pumps...

Страница 13: ...n Gland 2 x Cable Ties RainSmartTM PUMP BOX 1 x RainSmartTM Controller 1 x Motorised Ball Valve 1 x Float Switch 1 x Dual Check Valve 1 x Plastic Threaded Tee 1 x Plastic Threaded Nipple 1 x Plastic T...

Страница 14: ...FIG 1...

Страница 15: ......

Страница 16: ...General Test B verify rain water level Perform General Test B2 Verify float sensor 2 No water being delivered by pump Perform General Test A verify RainSmartTM power supply Perform General Test E ver...

Страница 17: ...m General Test B2 Verify float sensor Tank empty Mains Water indicator ON Perform General Test D Verify Mains Valve operation TABLE 2 GENERAL TESTS The following general tests must be used in conjunct...

Страница 18: ...al If not return the RainSmartTM unit for service as a failure has occurred D Verify Mains Valve operation Press the test button Mains valve operates There is a visual indicator on top of the mains va...

Страница 19: ...orised workshop labour will be free of charge for the first 12 month period from date of the first consumer purchase when unit is found to have failed due to defective workmanship or material supplied...

Страница 20: ...y and fitness for a particular purpose exclusion of damages Rainsmart Australia Pty Ltd liability is limited to the cost of repair or replacement of the product Rainsmart Australia Pty Ltd shall not b...

Страница 21: ...Please do not return Warranty Retain for your records Purchased From Purchase Date Serial No Model No RAINSMART ASUTRALIA PTY LTD Australia Head Office RainSmart Australia Pty Ltd PO Box 835 Lutwyche...

Страница 22: ......

Отзывы: