What is it? 

The 

RainSmart

TM

 ‘Pump Box’ is basically your typical 

RainSmart

TM

 

+ Pump + 

Pump  Box  all  in  one,  neatly  and  fully  assembled  for  the  ease  of  you,  the 
consumer. The 

RainSmart

TM

 ‘Pump Box’ is used as a switch between Mains and 

precious Tank water. 

 
How it works? 

The 

RainSmart

TM

 ‘Pump Box’ comes fully assembled and works like a typical 

RainSmart

TM

.  The  Float  Switch  provided  senses  when  there  is  and  is  not 

sufficient  water  in  the  Tank  to  supply  your  Amenities.  If  there  is  water  in  the 
Tank,  the  Motorised  Ball  Valve  (blue  box  as  depicted  above)  closes  and  Tank 
water is pumped and directed to your Amenities. If there is no water in the Tank, 
the Motorised Ball Valve opens allowing Mains water to pass through the Dual 
Check Valve (gold valve beside Motorised Ball Valve as depicted above) to the 
Amenities.  Mains water  cannot pass through the  Pump as a check  valve in the 
Pumps press head prevents this from occurring.  

 

What you need? 

Installing  the 

RainSmart

TM

  ‘Pump  Box’  is  as  easy  as  4  simple  connections. 

Connect the Tank to the Pump. Connect the Mains line to the Dual Check Valve. 
Connect  the  Amenities  line  to  the  T-piece.  Lastly,  plug  the 

RainSmart

TM 

controller  into  a  Mains  power  outlet.  Please  note:  The  installation  of  the 

RainSmart

TM

 ‘Pump Box’ 

must 

be carried out by a 

licensed plumber

. However, 

a licensed electrician is not required. (To see Float Retention Gland installation 
and or setting Reserve Levels, refer to ‘5. INSTALLING FLOAT SWITCH’). 

 
 

Содержание RainSmart

Страница 1: ......

Страница 2: ...ION 6 MOUNTING RAINSMARTTM CONTROLLER 7 WIRING FLOAT SWITCH AND MOTORISED BALL VALVE 6 RAINSMARTTM QUICKSETUP 8 INSTALLING DUAL CHECK VALVE 8 INSTALLING FLOAT SWITCH 11 INSTALLING MOTORISED BALL VALVE...

Страница 3: ...ly with applicable local standards The low voltage connections need not be carried out by a qualified electrician but should be done in compliance with applicable standards Do not use long extension l...

Страница 4: ......

Страница 5: ...ies If there is no water in the Tank the Motorised Ball Valve opens allowing Mains water to pass through the Dual Check Valve gold valve beside Motorised Ball Valve as depicted above to the Amenities...

Страница 6: ...duct complies with relevant electrical standards and has Watermark approval number 23029 1 GENERAL INFORMATION The RainSmartTM controller can be used in either above ground or below ground tank instal...

Страница 7: ...3 WIRING FLOAT SWITCH AND MOTORISED BALL VALVE The Float Switch and Motorised Ball Valve are low voltage for your safety...

Страница 8: ...It is necessary to install the Dual Check Valve as described This installation method will adhere to government requirements The installation must be carried out by a licensed plumber 5 INSTALLING FL...

Страница 9: ...Float lead at the top of the tank raise the Float head by pulling up the Float lead When you are content with the Float head height which may be a quarter or half way up the tank place a mark on the...

Страница 10: ...FIG 4...

Страница 11: ...at switch once again in the upright position so that the valve closes Once closed pull the valve plug out from the socket The valve should open You may also use the test button to check the valve oper...

Страница 12: ...s the result of an acceptable water level sensed by the Float Switch The Motorised Ball Valve will be in the closed position Pump Auto Signifies the pump being controlled by the Float Switch The pumps...

Страница 13: ...n Gland 2 x Cable Ties RainSmartTM PUMP BOX 1 x RainSmartTM Controller 1 x Motorised Ball Valve 1 x Float Switch 1 x Dual Check Valve 1 x Plastic Threaded Tee 1 x Plastic Threaded Nipple 1 x Plastic T...

Страница 14: ...FIG 1...

Страница 15: ......

Страница 16: ...General Test B verify rain water level Perform General Test B2 Verify float sensor 2 No water being delivered by pump Perform General Test A verify RainSmartTM power supply Perform General Test E ver...

Страница 17: ...m General Test B2 Verify float sensor Tank empty Mains Water indicator ON Perform General Test D Verify Mains Valve operation TABLE 2 GENERAL TESTS The following general tests must be used in conjunct...

Страница 18: ...al If not return the RainSmartTM unit for service as a failure has occurred D Verify Mains Valve operation Press the test button Mains valve operates There is a visual indicator on top of the mains va...

Страница 19: ...orised workshop labour will be free of charge for the first 12 month period from date of the first consumer purchase when unit is found to have failed due to defective workmanship or material supplied...

Страница 20: ...y and fitness for a particular purpose exclusion of damages Rainsmart Australia Pty Ltd liability is limited to the cost of repair or replacement of the product Rainsmart Australia Pty Ltd shall not b...

Страница 21: ...Please do not return Warranty Retain for your records Purchased From Purchase Date Serial No Model No RAINSMART ASUTRALIA PTY LTD Australia Head Office RainSmart Australia Pty Ltd PO Box 835 Lutwyche...

Страница 22: ......

Отзывы: