12 |
120-Volt, 20-Amp Duplex Outlets (5-20R) GFCI:
Each outlet is capable of carrying a maximum of
20 amps on a single receptacle or a combination
of both receptacles.
30-Amp Circuit Breaker:
Circuit breaker limits
the current that can be delivered through the 120-
volt outlet to 30amps.
120-Volt, 30 Amp Twistlock Outlet (L5-30R):
Outlet can supply 120V output.
120/240-Volt, 30-Amp Twist Lock Outlet
(NEMA L14-30R):
Outlet can supply either
120V or 240V up to 30 amps.
120/240-Volt, 50-Amp Outlet (NEMA 14-50R):
Outlet can supply either 120V or 240V up
to 50 amps.
Main Circuit Breaker:
The main circuit breaker
controls total output of all outlets to protect the
generator.
Ground Terminal:
The ground terminal is used to
ground the generator.
Fuel Selector Switch:
Select and turn on gas or
propane.
Electric Start Switch:
Hold in Start position to start
generator. Switch to
STOP
to stop the engine.
Data Center:
The VFT Meter is an LED display
that will rotate through volts, frequency, and
lifetime run hours. You can press the
MODE
button to cycle through the different displays.
The frequency and voltage can vary +/- 5% and
still be within tolerance.
20-Amp Circuit Breaker:
Circuit breaker limits the
current that can be delivered through the 120-volt
outlet to 20amps.
CONTROL PANEL FEATURES
1
8
9
10
11
2
3
4
5
6
7
3
4
6
8
7
9
2
1
10
FEATURES
5
Frequency in hertz
Lifetime run hours
Voltage
FU
EL
S
E
LE
C
T
O
R
S
W
IT
C H
G A S
O L I N E
P R O P
A N E
NEUTRAL BONDED
TO FRAME
VFT METE R
AC BREAKER
20 A
ON
OF F
AC BREAKER
30 A
ON
OF F
120V AC 20 A
5-20R GFCI
120V AC 30 A
L5-30 R
120/240V AC 30 A
L14-30 R
120/240V AC 50 A
L14-50 R
MAIN BREAKE R
ON
OF F
RU N
STAR T
ELECTRIC START
STOP
11
Содержание HYBRID DUAL FUEL R12000DF
Страница 28: ...28 Version 07 06 18KD Rev2 RainierPower com...