STOPPING THE GENERATOR

Normal Operation

During normal operation, use the following steps to 

stop your generator:

1.  Remove any connected loads from the control 

panel receptacles.

2.  Allow the generator to run at “no load” to reduce 

and stabilize engine and alternator temperatures.

3.  If you are operating on gas move the fuel shut off 

valve to 

OFF

. If you are operating on propane shut 

off the tank valve. Wait for engine to shut off due to 

lack of fuel.

4.  Position the engine control switch to 

STOP

.

During an Emergency

If there is an emergency and the generator must be 

stopped quickly, position the electric start switch to the 

STOP

 position immediately.

WARNING

Internal pressure can build in the engine 

crankcase while the engine is running. 

Removing the oil fill plug/ dipstick while 

the engine is hot can cause extremely 

hot oil to spray out of the crankcase and 

can severely burn skin. Allow engine 

oil to cool for several minutes before 

removing the oil fill plug/dipstick.
Always perform maintenance in a well- 

ventilated area. Gasoline fuel and fuel 

vapors are extremely flammable and can 

ignite under certain conditions.

WARNING

Avoid accidentally starting the 

generator during maintenance by 

removing the spark plug boot from 

the spark plug. For electric start 

generators, also disconnect the 

battery cables from the battery 

(disconnect the black negative (-) 

cable first) and place the cables away 

from the battery posts to avoid arcing.

Allow hot components to cool to 

the touch prior to performing any 

maintenance procedure.

MAINTENANCE

Engine Switch - STOP

Fuel Shut Off - OFF

Propane Tank Valve - CLOSED

BEFORE PERFORMING MAINTENANCE ON THE GENERATOR, REVIEW THE SAFETY SECTION  

STARTING ON PAGE 5, AS WELL AS THE FOLLOWING SAFETY MESSAGES.

ON

OFF

OPERATION

 

START 

RUN 

STOP

Содержание HYBRID DUAL FUEL R12000DF

Страница 1: ...R12000DF Dual Fuel OPEN FRAME Generator GASOLINE 9500 Running Watts 12000 Peak Watts PROPANE 8550 Running Watts 10800 Peak Watts...

Страница 2: ...se you and others to be seriously hurt or killed Model Number Running Watts Peak Watts Gasoline Tank Size G Rated Speed RPM Ignition Type Spark plug Engine Disp cc Stroke X Bore Oil Capacity qt Oil Ty...

Страница 3: ...register your generator you will need to locate the following information RAINIER PRODUCT REGISTRATION FORM PERSONAL INFORMATION GENERATOR INFORMATION First Name _____________________________________...

Страница 4: ...cation Selection 13 Grounding the Generator 13 High Altitude Operation Conversion Kits 13 Power Cord 14 Engine Fluids and Fuel 15 Adding Gasoline to the Fuel Tank 15 Connecting LPG Tank 16 Starting th...

Страница 5: ...NGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CA...

Страница 6: ...ap with the engine running Never refuel the generator while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank with gasoline Keep sparks...

Страница 7: ...sive and flammable Explosions and fire can cause severe burns or death Gasoline and gasoline vapor Gas Gasoline is highly flammable and explosive Gas expands and contracts with different temperatures...

Страница 8: ...e wheel kit is designed for use on this generator only INSTALLING FEET TO FRAME 1 Place generator on a flat surface 2 Place a piece of cardboard or other soft material to tip the generator onto to pro...

Страница 9: ...when connecting battery cables ALWAYS disconnect the negative battery cable black boot first when disconnecting battery cables NEVER connect the negative battery cable black boot to the positive post...

Страница 10: ...t breakers and outlets Battery Included for electric start models Oil Fill Plug Dipstick Must be removed to add and check oil FEATURES Oil Drain Plug Must be removed to drain engine oil Propane Hook U...

Страница 11: ...ervicing the engine or the spark plug CARB Canister Required for models sold into and used in California Muffler and Spark Arrester Avoid contact until engine is cooled down Spark arrestor prevents sp...

Страница 12: ...tor Switch Select and turn on gas or propane Electric Start Switch Hold in Start position to start generator Switch to STOP to stop the engine Data Center The VFT Meter is an LED display that will rot...

Страница 13: ...electrical shock due to faulty appliances High Altitude Operation Engine power is reduced the higher you operate above sea level Output will be reduced approximately 3 5 for every 1000ft of increased...

Страница 14: ...the responsibility of the user only This table is intended for reference only The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and...

Страница 15: ...ing the first five hours of operating the generator make sure to not exceed 50 of the rated running watts until the unit is broken in properly Make sure to vary to load occasionally to allow stator wi...

Страница 16: ...e propane tank and disconnect LPG hose when not in use OPERATION BEFORE STARTING THE GENERATOR BEFORE STARTING THE GENERATOR REVIEW SAFETY SECTION STARTING ON PAGE 5 Before attempting to start the gen...

Страница 17: ...ce for start up FOR GASOLINE a Move the fuel shut off valve to the ON position ON OFF b Turn fuel selector knob to GASOLINE Fuel Shut Off ON Fuel Selector GASOLINE FOR LPG PROPANE a Make sure the LPG...

Страница 18: ...the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin Allow engine oil to cool for several minutes before removing the oil fill plug dipstick Always p...

Страница 19: ...Change Cooling Features Check Clean Air Filter Check Clean Replace Spark Plug Check Clean Replace Spark Arrestor Check Clean Service more frequently if operating in dry and dusty conditions TABLE 2 M...

Страница 20: ...ize 4 With a damp rag clean around the oil fill plug dipstick 5 Remove oil fill plug dipstick Oil Fill Plug Dipstick 6 Check oil level When checking the engine oil remove the oil fill plug dipstick an...

Страница 21: ...on facility AIR FILTER MAINTENANCE WARNING Never use gasoline or other flammable solvents to clean the air filter Use only household detergent soap to clean the air filter Cleaning the Air Filter The...

Страница 22: ...plug boot by firmly pulling the plastic spark plug boot handle directly away from the engine NOTICE Never apply any side load or move the spark plug laterally when removing the spark plug Applying a...

Страница 23: ...e Switch is switched to STOP so the generator does not draw power from battery 2 Clean the generator as outlined in Cleaning the Generator 3 Drain all gasoline from the fuel tank as best as possible 4...

Страница 24: ...ck for overload condition 2 The power cord s plug connector is not fully engaged in the generator s outlet 2 Verify plug connector is firmly engaged in the generator s outlet 3 Faulty or defective pow...

Страница 25: ...buretor dispersing after operation 3 Normal no remedy is needed Poor performance or engine stalling on propane 1 Propane fuel line kinked or crushed 1 Inspect propane fuel line and remove kinks or oth...

Страница 26: ...ou must at your expense deliver or ship your Rainier generator to an Rainier Outdoor Power Equipment Authorized Service Dealer for warranty repairs which must occur within the applicable warranty peri...

Страница 27: ...rtime holiday or emergency labor Starting battery fuses light bulbs and engine fluids DISCLAIMER OF IMPLIED WARRANTIES This limited warranty is in lieu of all other expressed or implied warranties inc...

Страница 28: ...28 Version 07 06 18KD Rev2 RainierPower com...

Отзывы: