background image

ENGLISH

29

may  cause  an  interference  to  radio  communica-
tions. However, we cannot
exclude that any interferences happen.
If this equipment causes interferences to
radio  or  television  reception,  which  can  be  de-
termined  turning  on  and  off  the  equipment,  the 
user has to take the following measures to try to 
eliminate them:
Reorient or relocate the receiving antenna.
•  Increase  the  separation  between  device  and 
receiver.
• Connect the equipment to a socket of a circuit 
different from the circuit to which  the receiver  is 
connected.
• Consult the dealer or an experienced radio / TV 
technician.

Warning: This device is not designed
for use by children or disable people
without supervision. Supervise children
to avoid that they play with the device.
Caution: Relay activation pump and the main 
valve
The controller allows you to operate a master 
valve or a pump during operation of any station. 
Connect a relay cable * (or master valve) to the 
“pump” and the other cable to the “common” 
exit of the controller.
* relay activation of the pump sold separately

Warranty and Declarations
RAIN spa, guarantees its customers that its pro-
ducts will be free from defects in materials and 
manufacturing for a period of two years from the 
purchase date.
For a period of two years from the purchase 
date we replace defective parts free of charge 
or components that will reveal defects if used in 
the normal conditions of use and maintenance 
(requiring proof of purchase).
We reserve the right to inspect the defective part 
before replacing it.
RAIN spa will not be responsible for any costs or 
accessories or consequential damages, caused 
by a defect of the product. 
The responsibility of RAIN spa under this
warranty is limited only to the replacement
of defective components.

To exercise your right to warranty, return the unit 
to your dealer with a copy of the receipt of
payment.

Содержание i-dial

Страница 1: ...N N O VAT I V E I R R I G AT I O N S Y S T E M S I EN INSTRUCTIONS Vac...

Страница 2: ...DAY SETTING Pag 24 IRRIGATION PLANNING Pag 25 MANUAL START Pag 26 FUNZIONI AGGIUNTIVE BUDGET Pag 27 ADDITIONAL FEATURES EXTRA PUMP SENSOR Pag 28 PROBLEM SOLVING DESCRIPTION The new controller I DIAL...

Страница 3: ...cluded Output rain sensor programmable per station Function OFF Function Low battery No permanent memory Technical features OUTDOOR version 4 6 8 stations Model outdoor with internal transformer Opera...

Страница 4: ...cluded Output rain sensor programmable per station Function OFF Function Low battery No permanent memory Technical features OUTDOOR version 4 6 8 stations Model outdoor with internal transformer Opera...

Страница 5: ...ART RAIN DELAY DURATION WE EVERY TU ALL MO DAY SA ZONE FR TH SU B A HOURS C D LOW PROG NEXT START FERTILIZER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 indoor model outdoor model WARNING The version with the...

Страница 6: ...mer Input sensor Rain sensor input Pump control or master valve Output M Sector output 1 8 The button CLEAR eliminates programming 16 Protection fuse 1 0 A 17 button RESET restarts the controller 18 E...

Страница 7: ...he area and it will be connected to one of the outputs numbered in the terminal compartment and the second one is the common cable that will be connected to the Exit C in the terminal compart ment alo...

Страница 8: ...common wire CONNECTING VALVE WIRES TO THE TIMER Remove the terminal compartment cover Strip _ 6mm of the plastic insulation off the end of each wire Determine which valve you want to connect to which...

Страница 9: ...is not plugged in Insert one of the two power leads from the transformer into each terminal It will be necessary to open the terminal to allow for wire insertion or removal To do this you will need t...

Страница 10: ...of the week with and buttons press ENTER to con rm After adjusting the time you can turn the cursor to the right to continue with the watering cycles programming or to the left to return to the auto f...

Страница 11: ...ed SPA TIME START A PROG The controller I Dial is equipped with 4 programs A B C D completely independent and programmable by following three simple steps Each program allows a daily start and can be...

Страница 12: ...3 minutes in this function Turn the circular cursor on the symbol WATERING DAYS the message MO will start to ash Press to irrigate in the day ashing press ENTER to continue in the next days press if y...

Страница 13: ...with the function BUDGET different from 100 SPA budget EXAMPLE the controller is programmed to per form a watering cycle at 07 00 AM with irrigation times of 10 minutes per zone If we reduce the perc...

Страница 14: ...ENTER to access the function modify with the or buttons the word ON OFF ashing and press ENTER to con rm and move to the next zone To return to the Initial screen press again EXTRA EXAMPLE The garden...

Страница 15: ...ak voltage Reset the programmer The controller irri gates endlessly Too many start times have been programmed Set up again the controller PROBLEM SOLVING Any unauthorized changes of this Warning units...

Страница 16: ...e a master valve or a pump during operation of any station Connect a relay cable or master valve to the pump and the other cable to the common exit of the controller relay activation of the pump sold...