• It will be necessary to open the terminal to 
allow for wire insertion or removal.
To do this you will need to use a small phillips 
head screwdriver.
• Connect the common wire to the terminal 
labeled “com”

CONNECTING THE TRANSFORMER

• With the wiring terminal shroud off, 

 nd the 

two terminal holes labeled “24vac”.
Make sure the transformer is not plugged in. 
Insert one of the two power leads
from the transformer into each terminal.
• It will be necessary to open the terminal to 
allow for wire insertion or removal.
To do this you will need to use a small phillips 
head screwdriver.
• Plug in transformer

WARNING: DO NOT LINK TWO OR MORE 
TIMERS TOGETHER WITH ONE

TRANSFORMER.
• Slide the shroud back on.

RAIN SENSOR

• A rain sensor or other type of micro-switch 

weather sensor may be connected to
the controller. The purpose of the sensor is to 
stop watering when precipitation is
suf

 cient.

Содержание i-dial

Страница 1: ...N N O VAT I V E I R R I G AT I O N S Y S T E M S I EN INSTRUCTIONS Vac...

Страница 2: ...DAY SETTING Pag 24 IRRIGATION PLANNING Pag 25 MANUAL START Pag 26 FUNZIONI AGGIUNTIVE BUDGET Pag 27 ADDITIONAL FEATURES EXTRA PUMP SENSOR Pag 28 PROBLEM SOLVING DESCRIPTION The new controller I DIAL...

Страница 3: ...cluded Output rain sensor programmable per station Function OFF Function Low battery No permanent memory Technical features OUTDOOR version 4 6 8 stations Model outdoor with internal transformer Opera...

Страница 4: ...cluded Output rain sensor programmable per station Function OFF Function Low battery No permanent memory Technical features OUTDOOR version 4 6 8 stations Model outdoor with internal transformer Opera...

Страница 5: ...ART RAIN DELAY DURATION WE EVERY TU ALL MO DAY SA ZONE FR TH SU B A HOURS C D LOW PROG NEXT START FERTILIZER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 indoor model outdoor model WARNING The version with the...

Страница 6: ...mer Input sensor Rain sensor input Pump control or master valve Output M Sector output 1 8 The button CLEAR eliminates programming 16 Protection fuse 1 0 A 17 button RESET restarts the controller 18 E...

Страница 7: ...he area and it will be connected to one of the outputs numbered in the terminal compartment and the second one is the common cable that will be connected to the Exit C in the terminal compart ment alo...

Страница 8: ...common wire CONNECTING VALVE WIRES TO THE TIMER Remove the terminal compartment cover Strip _ 6mm of the plastic insulation off the end of each wire Determine which valve you want to connect to which...

Страница 9: ...is not plugged in Insert one of the two power leads from the transformer into each terminal It will be necessary to open the terminal to allow for wire insertion or removal To do this you will need t...

Страница 10: ...of the week with and buttons press ENTER to con rm After adjusting the time you can turn the cursor to the right to continue with the watering cycles programming or to the left to return to the auto f...

Страница 11: ...ed SPA TIME START A PROG The controller I Dial is equipped with 4 programs A B C D completely independent and programmable by following three simple steps Each program allows a daily start and can be...

Страница 12: ...3 minutes in this function Turn the circular cursor on the symbol WATERING DAYS the message MO will start to ash Press to irrigate in the day ashing press ENTER to continue in the next days press if y...

Страница 13: ...with the function BUDGET different from 100 SPA budget EXAMPLE the controller is programmed to per form a watering cycle at 07 00 AM with irrigation times of 10 minutes per zone If we reduce the perc...

Страница 14: ...ENTER to access the function modify with the or buttons the word ON OFF ashing and press ENTER to con rm and move to the next zone To return to the Initial screen press again EXTRA EXAMPLE The garden...

Страница 15: ...ak voltage Reset the programmer The controller irri gates endlessly Too many start times have been programmed Set up again the controller PROBLEM SOLVING Any unauthorized changes of this Warning units...

Страница 16: ...e a master valve or a pump during operation of any station Connect a relay cable or master valve to the pump and the other cable to the common exit of the controller relay activation of the pump sold...

Отзывы: