WS-PRO2 Weather Station Manual
GT
27176
Page 61 of 61
•
Make sure the battery voltage is between 9.6 and 16 VDC.
•
Verify sensors are plugged into the correct bulkhead
connector and locking ring is securely in place (see Figure
17). Check connectors for any corrosion on pins.
•
If Smart Weather is used to create the station program
double check the wiring diagram to see if it matches the
physical wiring on the bulkhead connectors on the back of
the enclosure.
Unreasonable Results Displayed in an Input Location
•
Inspect the sensor for damage and/or contamination.
•
Make sure the sensor is plugged into the correct bulkhead
connector on the back of the enclosure.
6999 or 99999 Stored in Final Storage (or Storage Module)
•
Something is wrong with the datalogger and/or sensor(s).