WS-PRO2 Weather Station Manual
GT
27176
Page 23 of 61
3.4.3 Telephone Connected Using Telephone Company
Lines
The Telephone Company needs to run a direct burial telephone
cable to the weather station and terminate it near the base of the
weather station. This needs to be a modem quality type telephone
line with a separate call number.
The “TIP” line of the telephone cable shall be connected to the
WHITE (“TIP”) wire of a 20’telephone patch cable, furnished as
part of the weather station, marked - 2 conductor cable with
WHITE (“TIP”) and BLACK (“RING”) pair of wires. The “RING”
line of the telephone cable shall be connected to the BLACK
(“RING”) wire of the telephone patch cable. Splices shall be made
using 3-M DBY Direct Burial connectors. The splices for the phone
line shall be made in the valve box, where the power wiring splices
are made and where the MGP-1 grounding plate assembly with an
MSP-1 surge arrestor mounted in it, is attached to one rod of a 3-
rod grounding grid. Refer to FIGURE 14 below.
This telephone patch cable shall be routed through the 1 ½”
diameter long sweep elbow to the base of the weather station.
Содержание WS-PRO2
Страница 22: ...WS PRO2 Weather Station Manual GT 27176 Page 22 of 61 Figure 13...
Страница 24: ...WS PRO2 Weather Station Manual GT 27176 Page 24 of 61 Figure 14...
Страница 26: ...WS PRO2 Weather Station Manual GT 27176 Page 26 of 61 Figure 15...
Страница 28: ...WS PRO2 Weather Station Manual GT 27176 Page 28 of 61 Figure 17...
Страница 32: ...WS PRO2 Weather Station Manual GT 27176 Page 32 of 61 Figure 20...
Страница 33: ...WS PRO2 Weather Station Manual GT 27176 Page 33 of 61 Figure 21...
Страница 46: ...WS PRO2 Weather Station Manual GT 27176 Page 46 of 61 Figure 32...
Страница 51: ...WS PRO2 Weather Station Manual GT 27176 Page 51 of 61 Figure 36 Figure 37 Leveling Screws Leveling Screws...