PRR S-2 Turbine Operating Instructions

TRANSFORMER COMPATIBILITY AND
WIRING CHART

  ProtoSounds® is designed to work with any standard AC transformer that
uses a “Pure Sine-Wave" format.  The chart below lists the many Lionel®
compatible transformers, such as the Lionel KW or ZW models.  In
addition, the chart details how the terminals on these compatible
transformers should be attached to your layout.  The Trainmaster system
from Lionel® will not function correctly with ProtoSounds® without
disrupting the sound effects. Therefore, whenever ProtoSounds® senses that 
the Trainmaster system is being used, it automatically disables
ProtoSounds® sound effects.  The operator retains control over the engine,
but no sound effects will play. 

Transformer

Model

Center Rail

Outside Rail

Min/Max.

Voltage

Power

Rating

Transformer

Type

Lionel 1032

U

A

5-16v*

90-Watt

Standard

Lionel 1032M

U

A

5-16v*

90-Watt

Standard

Lionel 1033

U

A

5-16v*

90-Watt

Standard

Lionel 1043

U

A

5-16v*

90-Watt

Standard

Lionel 1043M

U

A

5-16v*

90-Watt

Standard

Lionel 1044

U

A

5-16v*

90-Watt

Standard

Lionel 1053

U

A

8-17v

60-Watt

Standard

Lionel 1063

U

A

8-17v

60-Watt

Standard

All-Trol

Left Terminal

Right Terminal

0-24v

300-Watt

Electronic

Cab-1/Powerma

ster

A

U

0-18v

135V.A.

Electronic

Dallee Hostler

Left Terminal

Right Terminal

Lionel LW

A

U

8-18v

75-Watt

Standard

Lionel KW

A or B

U

6-20v

190-Watt

Standard

MRC Tech II

Left Terminal

2

nd

 From Left

0-15v*

40V.A.

Electronic

Lionel MW (not
recommended)

Outside Track

Terminal

Inside Track

Terminal

5-16v*

50V.A.

Electronic

R.O.W.

Red Terminal

Black Terminal

0-24v

384-Watt

Standard

Lionel RS-1

Red Terminal

Black Terminal

0-18v

50V.A.

Electronic

Lionel RW

U

A

9-19v

110-Watt

Standard

Lionel SW

U

A

Unknown

130-Watt

Standard

 Lionel TW

U

A

8-18v

175-Watt

Standard

Lionel ZW

A or D

U

8-20v

275-Watt

Standard

MTH Z500

Red

Black

5-18v

50-Watt

Electronic

MTH Z750

 Red 

 Black 

5-18v

75-Watt

Electronic

MTH Z4000

 Red 

 Black 

5-22v

390-Watt

Electronic

Содержание S-2 TURBINE STEAM

Страница 1: ...tock and accessories The locomotive and tender are equipped with either a electronic whistle or the Proto Sound digital sound and train control system which contains several deluxe features that are s...

Страница 2: ...to Sound Battery 17 Manual Volume Adjustment of Proto Sound 18 USING RESET TO PROGRAM PROTO SOUND 18 Entering RESET Options 19 Setting The Engine Volume 29 Programming For Squeaking Brake Operation 20...

Страница 3: ...el the reverse unit operates in the same manner that all reverse units function by using forward neutral and reverse states that are entered each time the throttle is turned on and off or by using the...

Страница 4: ...coat the interior engine components When the smoke output begins to diminish while running the engine an additional 10 15 drops of smoke fluid should be added or the smoke unit switch should be turned...

Страница 5: ...rack the reverse unit begins in RESET or what seems like a neutral state Power must be interrupted again to get the locomotive to enter the forward state It is this first RESET state that gives Proto...

Страница 6: ...rupting the power to put the engine in forward After you leave RESET your engine will operate normally in all the direction states of forward neutral and reverse Remember though once power is turned o...

Страница 7: ...button again If you want to keep the bell on while running the engine simply interrupt the power with the transformer throttle or the transformer directional switch and enter forward or reverse PROTO...

Страница 8: ...y the microprocessor there is no guarantee that you won t hear the same message repeated twice or more times SQUEAKING BRAKE SOUNDS Proto Sound equipped engines feature the ability to play the sound o...

Страница 9: ...l find the squeaking brake feature to be a very realistic way to simulate the sound of an engine slowing down for curves crossings or coming to a stop at a station side track or switch yard However yo...

Страница 10: ...in the Neutral State No additional wires or modifications are needed to enjoy these amazing sound effects The sounds themselves are randomly shuffled by the Proto Sound computer This gives the system...

Страница 11: ...OR Change Press Direction The Train Will Remain In Neutral It Will Continue to Play More Background Noises d Bell Horn Whistle Direction OR Change Press Direction The Train Will Remain In Neutral You...

Страница 12: ...eutral after it is armed You cannot interrupt the power twice to enter another direction and still have the FYS active You can now trigger the sounds to begin playing when you next enter Neutral Optio...

Страница 13: ...at 14 volts or higher the squeaking brakes sound will play Once the engine is stopped the throttle must be turned on to keep it in the neutral state Note Failure to turn the throttle back on within 3...

Страница 14: ...a few chimes of the bell the engine will begin moving in forward with the bell continuing to ring A few seconds later the bell will turn off and the engine will resume normal operation Note When ente...

Страница 15: ...equipped with an FYS programmed Proto Sound module If the second engine isn t equipped with FYS the only thing to remember is not to turn up the transformer throttle very high when entering Reverse in...

Страница 16: ...n the throttle OFF then release the horn whistle button After 2 seconds you will hear a short whistle blast IMMEDIATELY turn the throttle back on The engine is now locked and will continue in the prev...

Страница 17: ...T the 6 cell 7 2v battery found in most convenience stores The battery is continually charged from the track when power is applied above 10 volts and should last for up to five years In addition the N...

Страница 18: ...irection will lower the volume of all sounds bell whistle and enhanced neutral sounds For information on operating the RESET volume adjustment option see the section entitled Programming Proto Sound R...

Страница 19: ...ly Adjusting The Engine Volume Reset Feature 6 1 Clank 1 Clink Reset Feature 6 allows you to change the volume setting of the chuff sounds without affecting the volume of other sounds such as whistle...

Страница 20: ...the Neutral state When ON pressing the Horn Whistle button while in Neutral with 10V AC or less on the track will cause the Horn recording to sound To use cycle to Reset 25 and press the Horn Whistle...

Страница 21: ...on the track and the transformer throttles in the OFF position press the PROGRAM button for the track in use The display will read 00 and PG 2 Using the WST HRN button scroll the top display up to 27...

Страница 22: ...whistle button again you have now reset the remaining reset feature 27 chuff rate back to the factory setting All the reset features now have been set back to the factory settings Programming FYS Ope...

Страница 23: ...ard Resetting All Proto Sound Options To Factory Defaults Reset Feature 18 3 Clanks 3 Clinks Reset Feature 18 is the most powerful of the Reset features available Using Reset Feature 18 allows you to...

Страница 24: ...re 10 Once the boiler is removed the gear box can be opened up by unscrewing the two screws on the plate located in front of the motor Grease can then be applied into the gear box using a grease tube...

Страница 25: ...the grooved drive wheel Before the new tire can be installed you must make sure the old tire has been completely removed from the groove in the drive wheel Use a razor blade or small flatblade screwdr...

Страница 26: ...the engine to wobble A razor blade can be used to trim away any excess tire that doesn t seat itself inside the groove properly Replacement tires are available directly from MTH Electric Trains HEADLI...

Страница 27: ...utton is depressed fully the Proto Sound circuit may not recognize the signal Try pressing the whistle button slower taking approximately 1 second to fully depress the button BELL PROBLEMS REMEDY When...

Страница 28: ...ven after the short whistle blast sounds You are waiting too long to turn the throttle back on after the short whistle blast sounds The power must be turned back on immediately after the short whistle...

Страница 29: ...working order This system check requires 2 2 seconds to complete during which time the engine will play the steam startup sounds We recommend that you don t interrupt the power in RESET until the stea...

Страница 30: ...e So that the freight yard sound effects and operation is as realistic as possible ProtoSounds disables the reverse unit state whenever FYS is enabled This way the engine never goes into reverse as th...

Страница 31: ...5 16v 90 Watt Standard Lionel 1033 U A 5 16v 90 Watt Standard Lionel 1043 U A 5 16v 90 Watt Standard Lionel 1043M U A 5 16v 90 Watt Standard Lionel 1044 U A 5 16v 90 Watt Standard Lionel 1053 U A 8 1...

Страница 32: ...uld be followed including the following Read this and all related manuals transformer power supply locomotive etc thoroughly before using this device This device is not recommended for children under...

Страница 33: ..._ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________________________...

Страница 34: ..._ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________________________...

Страница 35: ..._ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________________________...

Страница 36: ...r sales receipt the Return Authorization number and a full description of the problem must be included to facilitate the repairs Please include the description regardless of whether or not you discuss...

Отзывы: