Operation, Rack and Digital HPAs
Configure COM2 Menu
Three softkeys are active:
[Softkey 1]—
Sets the serial port baud rate. Cycles one step
each time the
[Softkey 1]
is pressed. The step sequence is:
[Softkey 2]—
Sets parity. Cycles one step each time [Softkey 2]
key is pressed. The step sequence is:
None Even Odd None etc.
[Softkey 3]—
Sets the data stop bits. Toggles between 8/1 and 7/
2.
Press
Enter
to return to
Menu 4.
Set System Address
One soft key is active. Refer to Figure 14.
[Softkey 1]—
Not used.
[Softkey 2]—
Not used. Value to the left of this key shows current
address.
[Softkey 3]—
Not used. Value to the left of this key is the new
address you enter using the numeric keypad. [
Enter
] accepts
the value. [
Clear
] clears the line.
[Softkey 4]—
Return to
Setup Menu 4.
Figure 14, Address Menu
1200
2400
4800 9600
19.2
38.4
57.6
1200,
etc.