Quick Start Guide
WinLink 1000 Installation and Operation Manual
2
Installing WinLink 1000 Units
•
Drill (for wall mounting only)
•
IDU and ODU grounding cable
•
13 mm or 1/2
″
socket spanner
•
ODU to IDU cable if not ordered (Outdoor class, CAT-5e, 4 twisted
pairs)
•
Cable ties
•
Laptop running Windows 2000 or Windows XP
Before the installation
1.
Install the WinLink 1000 software on the laptop.
2.
Verify that all equipment and tools are available.
Performing Installation
Î
To install the ODU:
1.
At site A, route the ODU cable from the ODU location (on the roof) to
the IDU location (inside the building). The maximum length is 100m.
2.
Mount the ODU unit to the mast or wall, using the mounting kit.
3.
Connect the RJ-45 connectors to both ends of the cable, use the
pinout table and diagram below:
IDU
RJ-45
Wire
Color
Function
ODU
RJ-45
1 White/Green
Ethernet
(RxN)
1
Twisted
2 Green Ethernet
(RxT)
2
3 White/Orange
Ethernet
(TxT)
3
Twisted
4
Blue
Power (+)
4
5
White\Blue
Power (+)
5
Twisted
6 Orange
Ethernet
(TxN)
6
7 White/Brown
Power (
−
)
7
Twisted
8 Brown Power (
−
)
8
4.
Secure the ODU and ground cables to the mast or brackets using
cable ties.
5.
Repeat the procedure at site B.