4.2 Annual Service (required)
The following procedures should be followed annually to maintain the AIRaider
TM
:
• Clean solenoids and switch coil locations.
• Check all hose connections.
• Check and/or clean the blower air intake filter.
•
Check and/or clean any filters or strainer installed on the inlet line to the AIRaider
TM
.
• Check and clean inlet screen on pump.
• Using a wet/dry vac, clean sediment from bottom of aeration tank if necessary.
• Clean (if necessary) tank and diffusers of all mineral build up.
• Chlorinate tank and lines by pouring ¼ cup of chlorine into the first aeration chamber.
• Check all control panel connections and electrical components (blower, pump, timer, fuses, etc.) for
proper operation.
• Check float switches for proper operation.
• Inspect vent line for possible obstructions.
• Run system through two cycles to ensure good working order.
• Perform Water Test.
4.3 Recommended Additional Service*
•
Every 3 years, replace all hoses.
•
Every 3-5 years, replace the solenoid valves.
* During Annual Service